IBM Support

PK19094: ALLOCATION ERROR RUNNING UTILITY EXCEPTION REPORT

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Customer gets an allocation error when allocating the TODS
    dataset in the IDLICOPY because the hlq.ISPF.PROFILE is a PDSE
    dataset.
    This means the sysadirblk =  NO_LIM and is invalid on the
    TSO ALLOC command where DIR has to be an integer.
    The TSO ALLOC is done with a LIKE('MODEL-DATASET-NAME') which
    means the attributes of the MODEL-DATASET are to be used to
    allocate a new dataset.
    This error occurs running the Utility Exception Report.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  ALL DATABASE CONTROL SUITE R320 USERS.      *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1.ALLOCATION ERROR AND COPY FAILURE FOR *
    *                      DATA SET HLQ.TEMP.ISPPROF RUNNING THE   *
    *                      UTILITY EXCEPTION REPORT.               *
    *                      2.MSG-IDLR287: 20; FILE TAILOR ERROR    *
    *                      IN MEMBER IDLIPR01. EXCEEDS MAXIMUM     *
    *                      LEVEL OF 8, IDLICEC8 RECORD-230         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    1. AN ALLOC/COPY ERROR IS ISSUED FOR DATASET HLQ.TEMP.ISPPROF
    FOR BATCH RECON AND COLLECT JOBS IF THE ORIGINAL ISPPROF IS A
    PDSE DATA SET.
    THE ALLOCATE COMMAND INCLUDES AN INVALID DIR(NO_LIM) FOR PDSE.
    THE DIR OPTION MUST BE NUMERIC.
    2. THERE IS A MISPLACED ENDSEL STATEMENT IN IPR/IC SKELETON,
    IDLICEC8, THAT CAUSES NESTED SELECT STATEMENTS TO EXCEED THE
    THE LIMIT. THE ERROR MAY ALSO APPEAR AS AN EMPTY ICEIN STATEMENT
    FOR IPR INTERNAL IMAGE COPIES.
    

Problem conclusion

  • 1. REXX EXEC IDLICOPY HAS BEEN MODIFIED TO ALLOW ALLOCATION OF
    PDSE PROFILE DATA SETS.
    2. SKELETON IDLICEC8 FOR PARALLEL REORG WITH IMAGE COPY JOBS
    HAS BEEN CORRECTED.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK19094

  • Reported component name

    IMS DB CNTL SUI

  • Reported component ID

    5655F7600

  • Reported release

    320

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2006-02-02

  • Closed date

    2006-03-01

  • Last modified date

    2006-04-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK12217

Modules/Macros

  • IDLC0001 IDLICEC8 IDLICOPY
    

Fix information

  • Fixed component name

    IMS DB CNTL SUI

  • Fixed component ID

    5655F7600

Applicable component levels

  • R320 PSY UK12217

       UP06/03/03 P F603

Fix is available