IBM Support

PK13142: IMAGE COPY OUTPUT DD STATEMENT IS MISSING OR DUMMY

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • DATAOUT DD statement is missing for Control Suite generated
    JCL for an IMAGE COPY using DFSDUMP0. The problem occurs when
    on panel IDLSOPT3, IC low level qualifier has a name specified
    and GDG/SMS contains *.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: ALL CONTROL SUITE R310 AND R320 USERS.       *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1.SMS(*) FIELD VALUE NOT SAVED ON PANEL *
    *                        IDLSOPT3 WHEN REDISPLAYED.            *
    *                      2.GENERATED JCL FOR OSAM DATABASES DOES *
    *                        NOT INCLUDE NECESSARY DEL/DEFS.       *
    *                      3.SERIOUS RC16 ERROR MSG FROM IDLGINPT  *
    *                        IN COLLECT/LOAD FUNCTIONS DOES NOT    *
    *                        INCLUDE REASONS FOR THE FAILURE.      *
    *                        FOR LARGE RECONS.                     *
    *                      4.CIC JOBS NEVER COMPLETE.              *
    *                      5.GENERATED CIC JCL OMITS DATAOUT       *
    *                        STATEMENTS.                           *
    *                      6.LIST.DB CMD FOR A SINGLE DB RETURNS   *
    *                        A REPORT OF ALL DBS IN THE RECON.     *
    *                        THIS COULD RESULT IN STORAGE ERRORS   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    COLLECT/LOAD PROBLEMS
     1. THE SMS(*) VALUE FOR IMAGE COPY DATA SETS ON PANEL
        IDLSOPT3 DOES NOT APPEAR TO BE SAVED. THE VALUE IS
        ACTUALLY SAVED, HOWEVER. BUT WHEN THE PANEL IS
        REDISPLAYED, THE VALUE IS NOT RETRIEVED FROM THE DATA
        TABLES. INSTEAD, THE FIELD IS AUTOMATICALLY FILLED WITH THE
        DEFAULT GDG(G) VALUE. IT MUST BE RESET TO SMS(*) EVERYTIME.
     2. OSAM DATABASES ARE INITIALLY COLLECTED WITH NO REUSE OPTION
        BECAUSE REUSE IS A VSAM PARAMETER. IF OSAM DATABASES ARE
        RECOLLECTED, HOWEVER, THE PARM MAY BE RESET TO REUSE. THIS
        ERROR COULD RESULT IN MISSING DEL/DEFS FOR THE OSAM DATABASE
        DATA SETS IN GENERATED JCL.
     3. THE MESSAGE FOR A RC16 COLLECT/LOAD SERIOUS ERROR FROM
        IDLGINPT DOES NOT LIST ANY OF THE POSSIBLE REASONS FOR THE
        ERROR, SUCH AS THE DBD COULD NOT BE LOADED FROM THE SETUP
        DBDLIB OR THERE COULD BE STORAGE ERRORS. IT'S DIFFICULT FOR
        A USER TO FIND AND CORRECT THE PROBLEM.
     JCL/JOB PROBLEMS
     1.THE GENERATED JCL FOR CONCURRENT IMAGE COPIES USES DISP=SHR
       RATHER THAN DISP=OLD FOR THE COPIED DATABASES. THIS CAN
       CAN LEAD TO CONTENTION AND A JOB THAT NEVER ENDS.
     2.THE GENERATED JCL FOR CONCURRENT IMAGE COPIES DOES NOT
       INCLUDE THE DATAOUT STATEMENTS FOR IC DATA SETS SPECIFIED
       WITH SMS(*) AND A LOW LEVEL QUALIFIER.
     3.THE LIST.DB COMMAND IN RECON MAINTENANCE RESULTS IN A LIST
       OF ALL THE RECON DBS, EVEN WHEN A SINGLE DB IS SPECIFIED.
       THIS CAN RESULT IN A SPACE PROBLEM IF THE RECON IS LARGE.
    

Problem conclusion

  • CONTROL SUITE CODE HAS BEEN MODIFIED TO CORRECT THE REPORTED
    PROBLEMS.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK13142

  • Reported component name

    IMS DB CNTL SUI

  • Reported component ID

    5655F7600

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2005-10-07

  • Closed date

    2006-01-17

  • Last modified date

    2006-02-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK10889 UK10890

Modules/Macros

  • IDLC0001 IDLGINPT IDLICD   IDLICD2  IDLRLIDB
    IDLRLI2B IDLSMAI2 IDLSOPT3
    

Fix information

  • Fixed component name

    IMS DB CNTL SUI

  • Fixed component ID

    5655F7600

Applicable component levels

  • R310 PSY UK10889

       UP06/01/19 P F601

  • R320 PSY UK10890

       UP06/01/19 P F601

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX88W","label":"IMS Database Control Suite"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310"}]

Document Information

Modified date: