A fix is available
APAR status
Closed as program error.
Error description
In cases where EXCEPTION profiles are used along with the REALLOCATION utility, some objects may incorrectly appear in the registration, START(UT), START(RW), or ALTER job steps of the generated job but not trigger any other utilities. If no other utilities are included in the job profile or all other utilities have an 'Exception Rule' set to 'R' (reject), the ALTER may be the only utility for that object in the generated job. Additionally, the registration, START(UT), and START(RW) steps may not have contained all qualifying objects. After this fix, if the PROCESS INDEXES flag in the OBJECT profile is set to "Y", registration START(UT), and START(RW) will change. If utilities are processed at the tablespace level that can also affect indexes, those corresponding indexes will now be included in the registration, START(UT), and START(RW) steps.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of DB2 Automation Tool. * **************************************************************** * PROBLEM DESCRIPTION: In cases where EXCEPTION profiles are * * used along with the REALLOCATION * * utility, some objects may incorrectly * * appear in the registration, START(UT), * * START(RW), or ALTER job steps of the * * generated job but not trigger any * * other utilities. If no other * * utilities are included in the job * * profile or all other utilities have * * an 'Exception Rule' set to 'R' * * (reject), the ALTER may be the only * * utility for that object in the * * generated job. Additionally, the * * registration, START(UT), and START(RW) * * steps may not have contained all * * qualifying objects. After this fix, * * if the PROCESS INDEXES flag in the * * OBJECT profile is set to "Y", * * registration START(UT), and START(RW) * * will change. If utilities are * * processed at the tablespace level that * * can also affect indexes, those * * corresponding indexes will now be * * included in the registration, * * START(UT), and START(RW) steps. * **************************************************************** * RECOMMENDATION: APPLY the PTF. * **************************************************************** Code has been changed to correct this condition.
Problem conclusion
APPLY the PTF.
Temporary fix
Comments
APAR Information
APAR number
PK13046
Reported component name
DB2 AUTOMATION
Reported component ID
5697G6300
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2005-10-06
Closed date
2005-12-13
Last modified date
2006-01-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
HAA$BUTE
Fix information
Fixed component name
DB2 AUTOMATION
Fixed component ID
5697G6300
Applicable component levels
R220 PSY UK10035
UP05/12/15 P F512
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUWB","label":"IBM Db2 Automation Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220","Edition":"","Line of Business":{"code":"","label":""}}]