IBM Support

PK12105: RECOVER UTILITY MAY END WITH RETURN CODE 8, MESSAGE 'INSUFFICIENT OPERANDS FOR KEYWORD TAPEUNITS'

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When generating a RECOVER utility using the PARALLEL option and
    zero
    in the 'Nbr of dynamic tape drives' field, the TAPEUNITS keyword
    is
    generated without a corresponding 'number of tape units'.  This
    causes
    the RECOVER utility to end with RETURN CODE 8. ( RC08 )
    

Local fix

  • Set the 'Nbr of dynamic tape drives' field to a value greater
    than
    zero or set the 'Parallel object restores' field to 'N'.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Automation Tool.                *
    ****************************************************************
    * PROBLEM DESCRIPTION: When generating a RECOVER utility       *
    *                      using the PARALLEL option and zero      *
    *                      in the 'Nbr of dynamic tape drives'     *
    *                      field, the TAPEUNITS keyword is         *
    *                      generated without a corresponding       *
    *                      'number of tape units'.  This causes    *
    *                      the RECOVER utility to end with         *
    *                      RETURN CODE 8. ( RC08 )                 *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK12105

  • Reported component name

    DB2 AUTOMATION

  • Reported component ID

    5697G6300

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2005-09-19

  • Closed date

    2005-09-26

  • Last modified date

    2005-10-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • HAARCVRC
    

Fix information

  • Fixed component name

    DB2 AUTOMATION

  • Fixed component ID

    5697G6300

Applicable component levels

  • R220 PSY UK07591

       UP05/09/29 P F509

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUWB","label":"IBM Db2 Automation Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
12 February 2021