A fix is available
APAR status
Closed as program error.
Error description
When using templates, some IMAGE COPY dataset names may be incorrectly resolved causing the IMAGE COPY utility to end with a return code 8.(RC08 RC8 ) Prior to this fix, using panel HAA$UCPN, 'LP Image Copy DSN Generation' to build the dataset name in a TEMPLATE could cause the DSN in the utility template to incorrectly omit the period (.) immediately before the GDG number. This fix corrects this problem. PLEASE BE AWARE: If prior to installing this fix, the DSN was manually changed on panel HAA$UCPN to include an additional period, this will cause the DSN to contain two periods before the GDG number. ** Any utility profiles that had been manually changed as a work around will have to be updated after this fix is applied.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of DB2 Automation Tool. * **************************************************************** * PROBLEM DESCRIPTION: When using templates, some IMAGE COPY * * dataset names may be incorrectly * * resolved causing the IMAGE COPY utility * * to end with a return code 8. * * (RC08 RC8) * **************************************************************** * RECOMMENDATION: APPLY the PTF. * **************************************************************** Code has been changed to correct this condition.
Problem conclusion
APPLY the PTF.
Temporary fix
Comments
APAR Information
APAR number
PK10201
Reported component name
DB2 AUTOMATION
Reported component ID
5697G6300
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2005-08-10
Closed date
2005-08-23
Last modified date
2005-10-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK06535
Modules/Macros
HAA$BDSN HAA$BMSG
Fix information
Fixed component name
DB2 AUTOMATION
Fixed component ID
5697G6300
Applicable component levels
R220 PSY UK06535
UP05/08/25 P F508
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUWB","label":"IBM Db2 Automation Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: