Error description
This fix disables the obsolete "FORCE(M)" CQMPARM. When QM is attempted to start using this obsolete CQMPARM, the startup attempt will now fail and will be accompanied by 2 error messages: * 1) CQM2101E - PARAMETER ERROR DETECTED FOR FORCE 2) CQM2110E - TERMINATING DUE TO ERRORS IN CQMPARMS INPUT * The first (CQM2102E) indicates the invalid use of an obsolete parameter in the CQMPARMs. The second (CQM2110E) to indicate that QM cannot continue and is terminating - again, due to the use of an obsolete CQMPARM.
Local fix
Remove obsolete FORCE(M) parm in CQMPARMS and cycle DB2 to make change effective.
Problem summary
**************************************************************** * USERS AFFECTED: Users of DB2 Query Monitor. * **************************************************************** * PROBLEM DESCRIPTION: This fix disables the obsolete * * "FORCE(M)" CQMPARM. When QM is * * attempted to start using this obsolete * * CQMPARM, the startup attempt will now * * fail and will be accompanied by 2 * * error messages: * * * * 1. CQM2101E - PARAMETER ERROR * * DETECTED FOR FORCE * * 2. CQM2110E - TERMINATING DUE TO * * ERRORS IN CQMPARMS INPUT * * * * The first (CQM2102E) indicates the * * invalid use of an obsolete parameter in * * the CQMPARMs. The second (CQM2110E) to * * indicate that QM cannot continue and is * * terminating - again, due to the use of * * an obsolete CQMPARM. * **************************************************************** * RECOMMENDATION: * **************************************************************** Code has been changed to correct this condition.
Problem conclusion
APPLY the PTF.
Temporary fix
Comments
APAR Information
APAR number
PK09132
Reported component name
DB2 QUERY MONIT
Reported component ID
5655E6701
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2005-07-19
Closed date
2005-08-10
Last modified date
2005-09-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK06168
Modules/Macros
CQM#PARM
Fix information
Fixed component name
DB2 QUERY MONIT
Fixed component ID
5655E6701
Applicable component levels
R210 PSY UK06168
UP05/08/17 P F508
Fix is available