A fix is available
APAR status
Closed as program error.
Error description
The "STCK to LRSN Delta" is primarily a zero value at most sites that use data sharing, but for those who have a non-zero value, the times of log records reported on will not be accurate, and this can result in missing data. Support for this field added in this APAR. A non-zero value can exist in this field if the RBA values are greater than the LRSN values at time of data sharing creation.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of DB2 Log Analysis Tool. * **************************************************************** * PROBLEM DESCRIPTION: The "STCK to LRSN Delta" is primarily * * a zero value at most sites that use * * data sharing, but for those who have a * * non-zero value, the times of log * * records reported on will not be * * accurate, and this can result in * * missing data. Support for this field * * added in this APAR. A non-zero value * * can exist in this field if the RBA * * values are greater than the LRSN * * values at time of data sharing * * creation. * **************************************************************** * RECOMMENDATION: * **************************************************************** Code has been changed to correct this condition.
Problem conclusion
APPLY the PTF.
Temporary fix
Comments
APAR Information
APAR number
PK05503
Reported component name
DB2 LOG ANALYSI
Reported component ID
5655E6601
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2005-05-09
Closed date
2005-06-24
Last modified date
2005-08-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
ALABSQL ALACREP ALAGLOAD ALAIN5 ALALF1 ALALF2 ALALF4 ALAMAIN ALAREC ALAREC2 ALATC H237130J
Fix information
Fixed component name
DB2 LOG ANALYSI
Fixed component ID
5655E6601
Applicable component levels
R130 PSY UK04874
UP05/07/07 P F507
R210 PSY UK04875
UP05/07/06 P F507
R220 PSY UK04876
UP05/07/06 P F507
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.