A fix is available
APAR status
Closed as program error.
Error description
The legacy COBOL run-time debugger event DpiNotifyNewProgramEntry always returned the compile unit name (PROGRAM-ID) when the compile unit received control, regardless of whether it received control at the primary or at a secondary entry. This is the preferred result, as in some contexts like an IMS region, applications may receive control at a secondary entry point that has the same eg. DLITCBL in each application. If the secondary entry point name is returned, it's not possible to trigger the debugger on a specific application.
Local fix
Don't use secondary entry points.
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V5 and later * * releases starting Debug Tool using DELAY * * DEBUG, DTCN or CADP profiles. * * * **************************************************************** * PROBLEM DESCRIPTION: The profiles are active, but Debug * * Tool does not start when the COBOL * * program is entered through an * * alternate entry point defined by the * * COBOL ENTRY statement. * * * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * * * **************************************************************** COBOL Runtime notified Debug Tool with an incorrect entry point name when the COBOL program was entered by an alternate entry point. FIXCAT keywords: COB0501T/K COB0502T/K COB0601T/K COB0602T/K
Problem conclusion
COBOL Runtime has been corrected to notify Debug Tool with the correct entry point name.
Temporary fix
Comments
APAR Information
APAR number
PI97696
Reported component name
LE ENT COBOL LI
Reported component ID
568819812
Reported release
790
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-05-07
Closed date
2018-06-13
Last modified date
2018-07-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
PI99069 UI56507 UI56508
Modules/Macros
IGZCEV4 IGZLLIBV IGZXAPI IGZXCDA IGZXDMR IGZXD24 IGZXLPIO IGZXLPKA IGZXLPKB IGZXLPKC IGZXLPKD IGZXLPKE IGZXLPKF IGZXLPKG IGZXPK2
Fix information
Fixed component name
LE ENT COBOL LI
Fixed component ID
568819812
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCVR7X","label":"Runtime"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]
Document Information
Modified date: