IBM Support

PI97145: Various Communication Errors May Occur; TCP/IP Port scan processing can cause assorted Agent error messages

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Various communication errors may occur, including: AUIX093S--An
    unexpected error occurred S0C1 abend in agent started task
    U4091 error, related to PTRACE function of UNIX
    Also, While running Port Scans to verify security policies of
    system networks, and the ports scanned include those used by
    the IMS STAP agent and associated sub-tasks. assorted error
    messages may be issued indicating unknown, unsolicited and
    invalid data packets being received by the IMS STAP code via
    the scanned port(s). These message can include, but are not
    limited to: AUIZ014E--Log-server: invalid data received from
    client: ip_address. BPXP011I THREAD xxxxxxx IN PROCESS
    yyyyyyyy, WAS TERMINATED DUE TO A PTHREAD QUIESCE OF TYPE 2.
    BPXP018I THREAD xxxxxxxx, IN PROCESS yyyyyyyyy, ENDED WITHOUT
    BEING UNDUBBED WITH COMPLETION CODE zzzzzzzz AND REASON CODE
    wwwwwwww.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IBM Security Guardium S-TAP for IMS *
    *                 on z/OS                                      *
    ****************************************************************
    * PROBLEM DESCRIPTION: While running Port Scans to verify      *
    *                      security policies of system networks,   *
    *                      and the ports scanned include those     *
    *                      used by the IMS STAP agent and          *
    *                      associated sub-tasks, assorted error    *
    *                      messages may be issued indicating       *
    *                      unknown, unsolicited and invalid data   *
    *                      packets being received by the IMS STAP  *
    *                      code via the scanned port(s).           *
    *                                                              *
    *                      These messages can include, but are     *
    *                      not limited to:                         *
    *                      AUIZ014E--Log-server: invalid data      *
    *                           received from client: ip_address.  *
    *                                                              *
    *                      BPXP011I THREAD  xxxxxxx IN PROCESS     *
    *                           yyyyyyyy, WAS TERMINATED DUE TO    *
    *                           A PTHREAD QUIESCE OF TYPE 2.       *
    *                                                              *
    *                      BPXP018I THREAD xxxxxxxx, IN PROCESS    *
    *                           yyyyyyyyy, ENDED WITHOUT BEING     *
    *                           UNDUBBED WITH COMPLETION CODE      *
    *                           zzzzzzzz AND REASON CODE wwwwwwww. *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Apply the supplied PTF to resolve this issue.
    

Problem conclusion

  • N/A
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI97145

  • Reported component name

    SEC GUAR STAP I

  • Reported component ID

    5655STM00

  • Reported release

    A00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-04-24

  • Closed date

    2018-06-29

  • Last modified date

    2018-08-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI56974 UI56975

Modules/Macros

  •    AUIAAACM AUIAAUGT AUIAAUTP AUIACBIM AUIACLIM
    AUIACSUI AUIADBRD AUIADDLI AUIADORD AUIADT@  AUIAGDSC AUIAGQHN
    AUIAPLMT AUIAPTLG AUIFAGTF AUIFDT@  AUIFHRDR AUIFSMF  AUILDT@
    AUILIMS  AUILIMSL AUILMDT@ AUILMMLG AUILMTRD AUILRRDR AUITACK
    AUITAGT  AUITDT@  AUITNACK AUITPERR AUITRCRD AUITREQ  AUITRESP
    AUITRPT  AUITRPTO AUIUACSA AUIUACUT AUIUCSUT AUIUDT@  AUIURAMG
    AUIURDT@ AUIURMIG AUIZAART AUIZACFB AUIZACFG AUIZACPB AUIZACXB
    AUIZAPIR AUIZCFGF AUIZCMN  AUIZCSPB AUIZDT@  AUIZFFLL AUIZMO@
    AUIZMSGS AUIZPAS  AUIZPLIN AUIZSLSV AUIZSM@  AUIZSMAN AUIZSSPC
    AUIZTCFG HAIWA00J HAIWA13J
    

Fix information

  • Fixed component name

    SEC GUAR STAP I

  • Fixed component ID

    5655STM00

Applicable component levels

  • RA00 PSY UI56974

       UP18/07/10 P F807

  • RA13 PSY UI56975

       UP18/07/10 P F807

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSCJM6A","label":"IBM Security Guardium S-TAP for IMS on z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A00","Edition":"","Line of Business":{"code":"LOB24","label":"Security Software"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A00","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
02 August 2018