A fix is available
APAR status
Closed as program error.
Error description
IMS Tools Discovery Utility HKTDDSC0 issues HKTD494W message when DBD is defined incorrectly or DBD is not defined to RECON data sets. HKTD494W VALIDATION FAILED - DBD xxxxxxxxx SKIPPED After IMS Tools Discovery Utility issues the HKTD494W message, it should release a CPOOL buffer for processing the DBD, however, it does not release the CPOOL buffer. When HKTD494W messages are issued for thousands of DBDs, IMS Tools Discovery Utility job becomes storage shortage and causes ABEND S80A or SC78.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: IBM Tools Base for z/OS V1.6 users * * (FMID=HAHN160) who use IMS Tools Discover * * Utility (HKTDDSC0) * **************************************************************** * PROBLEM DESCRIPTION: IMS Tools Discover Utility (HKTDDSC0) * * gets ABEND S80A or SC78 after a lot of * * HKTD494W messages. * **************************************************************** * RECOMMENDATION: * **************************************************************** IMS Tools Discovery Utility HKTDDSC0 issues HKTD494W message when DBD is defined incorrectly or DBD is not defined to RECON data sets. HKTD494W VALIDATION FAILED - DBD xxxxxxxxx SKIPPED After IMS Tools Discovery Utility issues the HKTD494W message, it should release a CPOOL buffer for processing the DBD, however, it does not release the CPOOL buffer. When HKTD494W messages are issued for thousands of DBDs, IMS Tools Discovery Utility job becomes storage shortage and causes ABEND S80A or SC78.
Problem conclusion
This APAR fixes HKTDWRDB to release the unused strage correctly. In addition, the following members are reassembled: HKTDDSC0 HKTDELDB HKTDELGP HKTDELPB HKTDWRGP HKTDWRPB
Temporary fix
Comments
APAR Information
APAR number
PI96116
Reported component name
TOOLS BASE
Reported component ID
5655V9300
Reported release
160
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-04-04
Closed date
2018-04-25
Last modified date
2018-09-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI55459
Modules/Macros
HKTDDSC0 HKTDELDB HKTDELGP HKTDELPB HKTDWRDB HKTDWRGP HKTDWRPB
Fix information
Fixed component name
TOOLS BASE
Fixed component ID
5655V9300
Applicable component levels
R160 PSY UI55459
UP18/08/10 P F808
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCJN3E","label":"IBM Tools Base"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"160"}]
Document Information
Modified date: