A fix is available
APAR status
Closed as program error.
Error description
When IGZXAPI is invoked to help process an exception, IGZXAPI itself suffers an exception. The original exception was caused by user data overlay of COBOL control blocks.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Enterprise COBOL V5+ users that use the * * IGZXAPI file and runtime information query * * routine. * **************************************************************** * PROBLEM DESCRIPTION: ABEND 0C4 when IGZXAPI is navigating * * the COBOL Runtime's control blocks, * * when some previous memory access has * * corrupted the control blocks. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** IGZXAPI needs to negative the COBOL Runtime's control blocks to collect the requested file and runtime information being queried. If the needed control blocks are corrupted, it may lead to ABEND 0C4 inside IGZXAPI.
Problem conclusion
IGZXAPI routine will check the COBOL Runtime's control blocks to ensure it's in a correct state before using the information in it to locate the file and runtime information. When the check fail, a negative return code is returned, instead of an ABEND.
Temporary fix
Comments
APAR Information
APAR number
PI95111
Reported component name
LE ENT COBOL LI
Reported component ID
568819812
Reported release
7B0
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-03-13
Closed date
2018-03-14
Last modified date
2018-04-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGZCER4 IGZCEV4 IGZCMGEN IGZCMGUE IGZLLIBV IGZXAPI IGZXCDA IGZXD24 IGZXDMR IGZXLPIO IGZXLPKA IGZXLPKB IGZXLPKC IGZXLPKD IGZXLPKE IGZXLPKF IGZXLPKG IGZXPK2
Fix information
Fixed component name
LE ENT COBOL LI
Fixed component ID
568819812
Applicable component levels
R7B0 PSY UI54470
UP18/03/28 P F803
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.