A fix is available
APAR status
Closed as program error.
Error description
In a CEEDUMP, the "User Level" data is incorrectly truncated to 4 characters. For example: COBOL Version = 05 Release = 02 Modification = 00 User Level = ' ' COBOL Version = 06 Release = 01 Modification = 00 User Level = 'P171' COBOL Version = 06 Release = 02 Modification = 00 User Level = 'P171'
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Enterprise COBOL 6.1 and later releases * * compiling and running programs that ABEND * * and produce CEEDUMP. * **************************************************************** * PROBLEM DESCRIPTION: The generated CEEDUMP truncates the * * "User Level" field to 4 characters; * * the correct length should be 8. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** COBOL Runtime control block for the "User Level" field has a size of 4 characters as opposed to be 8. When CEEDUMP processing prints the "User Level" from this field, the data is truncated to 4 characters long.
Problem conclusion
The COBOL Runtime control block "User Level" field has been corrected.
Temporary fix
Comments
APAR Information
APAR number
PI92327
Reported component name
LE ENT COBOL LI
Reported component ID
568819812
Reported release
7B0
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-01-11
Closed date
2018-01-24
Last modified date
2018-02-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGZCEV4 IGZCMGEN IGZCMGUE IGZLLIBV IGZXAPI IGZXCDA IGZXD24 IGZXDMR IGZXLPIO IGZXLPKA IGZXLPKB IGZXLPKC IGZXLPKD IGZXLPKE IGZXLPKF IGZXLPKG IGZXPK2
Fix information
Fixed component name
LE ENT COBOL LI
Fixed component ID
568819812
Applicable component levels
R7B0 PSY UI53199
UP18/01/27 P F801
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCVR7X","label":"Runtime"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
14 December 2020