A fix is available
APAR status
Closed as program error.
Error description
If the ESTAE routine associated with CEXEVTSR is driven during IMS Connect shutdown an ABEND0C1 results due to addressing issues within the ESTAE environment
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Connect Extensions V2.4 * **************************************************************** * PROBLEM DESCRIPTION: Potential CEXEVTSR ABEND0C1 on IMS * * Connect shutdown * **************************************************************** * RECOMMENDATION: * **************************************************************** If the ESTAE routine associated with CEXEVTSR is driven during IMS Connect shutdown an ABEND0C1 results due to addressing issues within the ESTAE environment
Problem conclusion
Incorrout parameter list area reference in the CEXEVTSR ESTAE routine has been corrected, avoiding the ABEND0C1
Temporary fix
Comments
APAR Information
APAR number
PI91389
Reported component name
IMS CONNECT EXT
Reported component ID
5655K4800
Reported release
240
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-12-11
Closed date
2018-01-25
Last modified date
2018-02-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
CEXEVTSR
Fix information
Fixed component name
IMS CONNECT EXT
Fixed component ID
5655K4800
Applicable component levels
R240 PSY UI53463
UP18/01/30 P F801
Fix is available