A fix is available
APAR status
Closed as program error.
Error description
When an Enterprise COBOL program calls another Enterprise COBOL COBOL using a Procedure Pointer, the Writable Static Area (WSA, CAACRENT) of the caller is not restored correctly.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 5.2 and later * * releases compiling and running programs * * that use PROCEDURE-POINTER data-items to * * call sub-programs residing in different * * Program Objects. * **************************************************************** * PROBLEM DESCRIPTION: The program terminates abnormally with * * S0C4 ABEND in IGZXPRS1. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** When a sub-program called by PROCEDURE-POINTER returns, the COBOL runtime library sets the Writable Static Area (WSA) address incorrectly for the caller program, leading to subsequent S0C4 ABEND in IGZXPRS1. This error occurs when the caller program and sub-program are residing in different Program Objects. FIXCAT keyword: COB0501T/K COB0502T/K COB0601T/K COB0602T/K
Problem conclusion
The COBOL runtime library has been fixed to set WSA addresses properly when handling PROCEDURE-POINTRE calls.
Temporary fix
Comments
APAR Information
APAR number
PI91271
Reported component name
LE ENT COBOL LI
Reported component ID
568819812
Reported release
7B0
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-12-07
Closed date
2017-12-14
Last modified date
2018-01-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI52552
Modules/Macros
IGZCEV4 IGZCMGEN IGZCMGUE IGZLLIBV IGZXAPI IGZXCDA IGZXD24 IGZXDMR IGZXLPIO IGZXLPKA IGZXLPKB IGZXLPKC IGZXLPKD IGZXLPKE IGZXLPKF IGZXLPKG IGZXPK2
Fix information
Fixed component name
LE ENT COBOL LI
Fixed component ID
568819812
Applicable component levels
R7B0 PSY UI52552
UP17/12/19 P F712
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7B0"}]
Document Information
Modified date:
17 September 2021