Error description

  • Event collection logic to mask password data in A4 event
    records can result in random storage overwrites when XID data
    is present on TRMA requests
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IMS Connect Extensions V2.4         *
    ****************************************************************
    * PROBLEM DESCRIPTION: Potential CEXTECL ABEND0C4 in DMP164    *
    *                      CSECT when XID present on TRMA requests *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Event collection logic to mask password data in A4 event
    records can result in random storage overwrites when XID
    data is present on TRMA requests
    

Problem conclusion

  • Support enhanced for A4 event collection when an XID data
    area is present, removing the possibility of inappropriate
    storage overwrites
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI91208

  • Reported component name

    IMS CONNECT EXT

  • Reported component ID

    5655K4800

  • Reported release

    240

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-12-06

  • Closed date

    2018-01-25

  • Last modified date

    2018-02-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI53463

Modules/Macros

  • CEXTECL
    

Fix information

  • Fixed component name

    IMS CONNECT EXT

  • Fixed component ID

    5655K4800

Applicable component levels

  • R240 PSY UI53463

       UP18/01/30 P F801

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX88S","label":"IMS Connect Extensions"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.4.0"}]

Document Information

Modified date:
22 October 2020