A fix is available
APAR status
Closed as program error.
Error description
During creation of an SLB, DB2 Recovery Expert issues a checkpoint and reads the BSDS to retrieve the previous checkpoint. If the RBA/LRSN is expanded, DB2 Recovery Expert incorrectly sorting the list of checkpoints and as a result not selecting the previous checkpoint. This results in a subsequent RESTORE SYSTEM LOGONLY using a checkpoint that may be months old.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IBM Recovery Expert z/OS. * **************************************************************** * PROBLEM DESCRIPTION: During creation of an SLB, DB2 * * Recovery Expert issues a checkpoint * * and reads the BSDS to retrieve the * * previous checkpoint. If the RBA/LRSN * * is expanded, DB2 Recovery Expert * * incorrectly sorting the list of * * checkpoints and as a result * * not selecting the previous checkpoint. * * This results in a subsequent RESTORE * * SYSTEM LOGONLY using a checkpoint * * that may be months old. * **************************************************************** * RECOMMENDATION: APPLY the PTF. * **************************************************************** Code has been changed to correct this condition.
Problem conclusion
APPLY the PTF.
Temporary fix
Comments
APAR Information
APAR number
PI90725
Reported component name
DB2 REC EXPERT
Reported component ID
5697H7400
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-11-27
Closed date
2017-12-07
Last modified date
2018-01-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI52506
Modules/Macros
ARY@BCKP
Fix information
Fixed component name
DB2 REC EXPERT
Fixed component ID
5697H7400
Applicable component levels
R320 PSY UI52506
UP17/12/16 P F712
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.