IBM Support

PI90567: COMPILE FAILS WITH ERROR: IGYCB7147-U INTERNAL ERROR DETECTED IN "CDA" PHASE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Compiler fails to compile the programs containing a PROCEDURE
    DIVISION with the USING phrase, while referencing
    unbounded data items with the BY REFERENCE phrase, and
    compiling with the TEST option by issuing error message:
     "IGYCB7147-U Internal error detected in "CDA" phase
    at ddpi_wcode_utilc:1439".
    

Local fix

  • Use NOTEST instead of TEST
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL 6.2 compiling      *
    *                 programs containing a PROCEDURE DIVISION     *
    *                 with the USING phrase, while referencing     *
    *                 unbounded data items with the BY REFERENCE   *
    *                 phrase, and compiling with the TEST option.  *
    ****************************************************************
    * PROBLEM DESCRIPTION: Compiler ABORT with message             *
    *                      IGYCB7147-U Internal error detected in  *
    *                      "CDA" phase at ddpi_wcode_utilc:1439    *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    The compiler was generating debug information that contained an
    invalid length value for an unbounded table item.
    

Problem conclusion

  • The compiler was updated to generate correct debug information
    for the unbounded table item.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI90567

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    620

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-11-22

  • Closed date

    2017-11-27

  • Last modified date

    2018-06-04

  • APAR is sysrouted FROM one or more of the following:

    PI89862

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • IGY8RWTU IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN
    IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4
    IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT
    IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8
    IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0
    IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2  IGYCOPI
    IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT
    IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4
    IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV   IGYEQCWI
    IGYMSGE  IGYMSGK  IGYMSGT  IGYQCBE  IGYSIDEK IGYZQDRV
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R620 PSY UP

       A

  • R621 PSY UP

       A

  • R622 PSY UI56122

       UP18/06/01 P F805

  • R62H PSY UP

       A

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: