A fix is available
APAR status
Closed as program error.
Error description
COBOL program compiled with the PARMCHECK option may fail to execute with the following error: CEE3204S The system detected a protection exception (System Completion Code=0C4).
Local fix
When using the PARMCHECK option, the user needs to explicitly specify the size of the PARMCHECK buffer instead of excepting the default. For example, use PARMCHECK(MSG,100) instead of PARMCHECK(MSG).
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 6.2 compiling and * * running programs with the PARMCHECK option. * **************************************************************** * PROBLEM DESCRIPTION: Runtime ABEND, with message: * * * * CEE3204S The system detected a * * protection exception (System * * Completion Code=0C4). From compile * * unit TESTPGM1 at entry point * * #SRVal000000001 at compile unit offset * * +00000304 at entry offset +00000084 at * * address 1F000304. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** An uninitialized variable in the PARMCHECK processing code could sometimes result in an inappropriate length being used for the PARMCHECK buffer.
Problem conclusion
The compiler was updated to fix the uninitialized variable problem in the PARMCHECK processing code.
Temporary fix
Comments
APAR Information
APAR number
PI89648
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
620
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-11-01
Closed date
2017-11-27
Last modified date
2018-06-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2 IGYCOPI IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYSIDEK IGYZQDRV
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R620 PSY UP
A
R621 PSY UP
A
R622 PSY UI56122
UP18/06/01 P F805
R62H PSY UP
A
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
12 December 2023