Fixes are available
APAR status
Closed as program error.
Error description
APPLID information not reset after a connection failure with IPIC
Local fix
Problem summary
CICS TG that uses the old auto generated APPLID during reconnect attempt after the CICS TS region restart.
Problem conclusion
CICS TG is corrected to not use old auto generated APPLID during reconnection attempt after CICS TS region restart.
Temporary fix
Comments
APAR Information
APAR number
PI89305
Reported component name
CICS TRNS GATE
Reported component ID
5724I8103
Reported release
920
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-10-24
Closed date
2017-11-23
Last modified date
2017-11-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CICS TRNS GATE
Fixed component ID
5724I8103
Applicable component levels
R920 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMJ2","label":"CICS Transaction Gateway"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.2","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]