Fixes are available
APAR status
Closed as program error.
Error description
When viewing large RPT reports in the Rational Test Control Panel (RTCP) web interface, RTCP can run out of memory and crash. The default Java heap size is not specified in the start scripts so it defaults to 512MB. WORKAROUND: 1. Shut down RTCP 2. Edit the setenv script Windows typically: C:\Program Files\IBM\RationalTestControlPanel\bin\setenv.bat Non-Windows typically: /opt/IBM/RationalTestControlPanel/bin/setenv.sh Add the preferred memory allocation by adding the -Xmx parameter: SET JVM_ARGS=-Xmx2048m -Djava.net.preferIPv4Stack=true -Djava.net.preferIPv6Addresses=false 3. Re-start RTCP
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of RTCP viewing large test reports or publishing and * * deploying large projects * **************************************************************** * PROBLEM DESCRIPTION: * * RTCP could run out of memory and crash. The memory * * allocation was not explicitly specified so could default to * * 512MB typically. * **************************************************************** * RECOMMENDATION: * * Follow the workaround detailed in this APAR or update to * * RTCP version 9.1.1.1. * ****************************************************************
Problem conclusion
This issue is fixed in version 9.1.1.1 of RTCP as 2GB of memory is reserved.
Temporary fix
Comments
APAR Information
APAR number
PI88522
Reported component name
RATL INTEGRA TE
Reported component ID
5725G79IT
Reported release
910
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-10-06
Closed date
2017-12-19
Last modified date
2017-12-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL INTEGRA TE
Fixed component ID
5725G79IT
Applicable component levels
R800 PSN
UP
R801 PSN
UP
R850 PSN
UP
R851 PSN
UP
R860 PSN
UP
R870 PSN
UP
R871 PSN
UP
R900 PSN
UP
R901 PSN
UP
R910 PSN
UP
R911 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSBLQQ","label":"Rational Test Workbench"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"910","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
18 October 2021