IBM Support

PI88097: HTK COPYDBRC ENDS WITH RC=00 EVEN THOUGH IHC01113E IS ISSUED.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • HTK COPYDBRC ends with RC=00 even though IHC01113E is issued.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IBM IMS Database Solution Pack V2.1 *
    *                 IMS HALDB Toolkit.                           *
    ****************************************************************
    * PROBLEM DESCRIPTION: HALDB Toolkit COPYDBRC function ends    *
    *                      with RC=00 even though IHC01113E OPEN   *
    *                      failed for DDname RECON1 is issued.     *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    HALDB Toolkit COPYDBRC function does not check return code after
    issuing IHC01113E OPEN failed for DDname RECON1 and continues
    the next process. So COPYDBRC function ends with RC=00 even
    though IHC01113E is issued.
    In addition, the following fix has been added in this APAR:
    - PTF level is shown in IHC01000I for COPYDBRC and BACKUPDBRC
      functions.
    

Problem conclusion

  • This APAR modifies the program so that HALDB Toolkit COPYDBRC
    function ends with RC=U0999 after issuing IHC01113E.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI88097

  • Reported component name

    IM DB SOLUTION

  • Reported component ID

    5655S7700

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-09-28

  • Closed date

    2017-10-09

  • Last modified date

    2017-11-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI50957

Modules/Macros

  • IHCULEV0 IHCWCPY0
    

Fix information

  • Fixed component name

    IM DB SOLUTION

  • Fixed component ID

    5655S7700

Applicable component levels

  • R210 PSY UI50957

       UP17/10/12 P F710

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.