Error description
DLL call code within a nested procedure fails to set the WSA pointer (CEECAACRENT) to that of the target DLL prior to transfering control. When the DLL gets control, its static data is not properly addressable and a failure will ensue, often an abend0c1 or abend0c4. DLL calls in the main body of the compile unit are unaffected. The first call works because that's the one where the run-time loads the DLL and transfers control to it, including setting up the WSA pointer.
Local fix
Call DLLs from mainline code
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V6.1 compiling * * programs at OPT(1|2) that make a call to a * * DLL, using the DLL compiler option or * * >>CALLINTERFACE DLL, from a nested program. * * * **************************************************************** * PROBLEM DESCRIPTION: The call fails and the program abends. * * * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * * * **************************************************************** The compiler needs to set up the CRENT pointer before making a DLL call, and restore it afterwards. The compiler was incorrectly removing the CRENT setup and restoration when the call was in a nested program.
Problem conclusion
The compiler was fixed to properly set up and restore the CRENT pointer when calling a DLL from a nested program.
Temporary fix
Comments
APAR Information
APAR number
PI85432
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
610
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-08-03
Closed date
2017-08-18
Last modified date
2018-08-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGYQCBE
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R610 PSY UI49694
UP17/08/25 P F708
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.1","Edition":"","Line of Business":{"code":"LOB70","label":"Z TPS"}}]
Document Information
Modified date:
05 September 2024