A fix is available
APAR status
Closed as program error.
Error description
Index Builder subordinate address space (SAS) terminates with return code 0 even when a DYNALLOC macro error occurs in WTO capture stripe data set. It should end with non-zero return code.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IMS Index Builder for z/OS, * * Version 3 Release 1 (FMID=H22O310). * **************************************************************** * PROBLEM DESCRIPTION: This APAR fixes some errors regarding * * the WTO capture summary function. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** When DYNALLOC macro fails while Index Builder subordinate address space (SAS) attempts to create a new WTO capture stripe data set (*.SSSSSS1), the following error occurs: (1) SAS erroneously opens the stripe data set and receives MSGIEC130I IIUCAPTR DD STATEMENT MISSING. (2) SAS terminates with return code zero, which should be 12. (3) The master address space (MAS) reports invalid completion code "ABEND U0000" for the SAS. (4) MAS may print obsolete WTO messages in the old stripe data set which caused the DYNALLOC error. This APAR also corrects unprintable or incorrect characters on 1st and 131-133rd column on WTO Capture Summary List.
Problem conclusion
Code has been changed to fix the errors.
Temporary fix
Comments
APAR Information
APAR number
PI81929
Reported component name
IMS INDEX BUILD
Reported component ID
5655E2400
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-05-19
Closed date
2017-05-24
Last modified date
2017-06-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI47566
Modules/Macros
IIUBSCTL IIUCMRGR IIUDASTE
Fix information
Fixed component name
IMS INDEX BUILD
Fixed component ID
5655E2400
Applicable component levels
R310 PSY UI47566
UP17/05/31 P F705
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89M","label":"IMS Index Builder"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0"}]
Document Information
Modified date: