APAR status
Closed as program error.
Error description
"Cannot write config file" is displayed when trying to save and exit from the DMHINSTL Set up panel.
Local fix
None Known
Problem summary
When a user who is not the owner of the RAA USS files/directories (and does not have root authority), the DMHINSTL Set up option changes cannot be saved, even if the user has group access to the files/directories and the group has write access. The message "Cannot write config file" is displayed when trying to save the changes.
Problem conclusion
Updated the DMHINSTL Set up option to no longer change the permission of existing directories. The Installation Guide has been updated with optional instructions for authorizing additional installers. The instructions involve adding the RAA installer group to the access control lists for configuration files/directories so that other installers have full permissions.
Temporary fix
Comments
APAR Information
APAR number
PI81913
Reported component name
RAA FOR SSTEM Z
Reported component ID
5655W5700
Reported release
610
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-05-19
Closed date
2017-05-23
Last modified date
2017-06-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
DMHINSTE
Fix information
Fixed component name
RAA FOR SSTEM Z
Fixed component ID
5655W5700
Applicable component levels
R610 PSY
UP