IBM Support

PI81295: BACKUP OF AOT TABLE FAILS WITH ERROR HLOU4076E AFTER MESSAGE HLOU5807W

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When running the BACKUP_ACCELERATOR command, the backup may fail
    with data conversion errors.  The following messages will be
    present in the job output:
      .
      HLOU5807W  Column (column name) has invalid data in Record=
      HLOU4076E Error converting data row to DB2 internal format.
    .
    This can occur when a table includes a mixture of nullable and
    not-nullable columns and the non-nullable columns are the first
    columns in the table.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IBM DB2 Analytics Accelerator       *
    *                 Loader for z/OS.                             *
    ****************************************************************
    * PROBLEM DESCRIPTION: When running the BACKUP_ACCELERATOR     *
    *                      command, the backup may fail with data  *
    *                      conversion errors.  The following       *
    *                      messages will be present in the job     *
    *                      output:                                 *
    *                        HLOU5807W  Column (column name) has   *
    *                          invalid data in Record=             *
    *                        HLOU4076E Error converting data row   *
    *                          to DB2 internal format.             *
    *                      This can occur when a table includes a  *
    *                      mixture of nullable and not-nullable    *
    *                      columns and the non-nullable columns    *
    *                      are the first columns in the table.     *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI81295

  • Reported component name

    IDAA LOADER ZOS

  • Reported component ID

    5639OLA00

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-05-09

  • Closed date

    2017-06-20

  • Last modified date

    2017-07-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    HLO62
    

Fix information

  • Fixed component name

    IDAA LOADER ZOS

  • Fixed component ID

    5639OLA00

Applicable component levels

  • R210 PSY UI48172

       UP17/06/24 P F706

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSKRKK","label":"IBM Db2 Analytics Accelerator Loader for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]