PI79998: IRO0032E SERVICE FAILURE, SERVICE: BPEPOST FUNC=POST RC=0000000C, RSN=00000000

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • IRO0032E SERVICE FAILURE, SERVICE: BPEPOST FUNC=POST
    RC=0000000C, RSN=00000000
    received occasionally.  Rerunning is usually successful.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All DRF/XF v1.1 Users.                       *
    ****************************************************************
    * PROBLEM DESCRIPTION: U0020-23 IROMSREM+02A8                  *
    ****************************************************************
    * RECOMMENDATION: Apply corrective maintenance for PI79998.    *
    ****************************************************************
    IROMSREM calls BPEPOST for an ECB with the POST bit already set.
    
    IRO0032E SERVICE FAILURE, SERVICE: BPEPOST FUNC=POST,
    RC=0000000C RSN=00000000
    BPE0006I IRE  TPRC TCB ABEND U0020-00000023 DIAG=1004000104
    BPE0006I MODULE ID = IROMIPRC+20091222+ EP = 321C51E8
    BPE0006I PSW = 077C1000 B21C5490    OFFSET = 000002A8
    BPE0006I R0-3   04000000 04000014 321C5540 0000000C
    BPE0006I R4-7   00000000 3223E508 32138EA0 80FDF2E0
    BPE0006I R8-11  321B5C50 321323D0 32101410 32132010
    BPE0006I R12-15 B21C51E8 3223F218 B21C5468 00000023
    

Problem conclusion

  • IROMSREM is corrected to test the POST bit before calling
    BPEPOST.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI79998

  • Reported component name

    IMS RCVR SOLUTN

  • Reported component ID

    5655V8600

  • Reported release

    110

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-04-13

  • Closed date

    2017-04-21

  • Last modified date

    2017-06-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI46627

Modules/Macros

  • IROMIPRC
    

Fix information

  • Fixed component name

    IMS RCVR SOLUTN

  • Fixed component ID

    5655V8600

Applicable component levels

  • R110 PSY UI46627

       UP17/05/11 P F705