IBM Support

PI78851: ABENDU2990 RSNC4C5C3A6 WHEN COMPRTN SPECIFIES KEY AND COMPRESSION ROUTINE IS USED

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • An ABENDU2990 RSNC4C5C3A6 may occur when an IMS COMPRTN
    specifies KEY
    and the segment data is compressed prior to being encrypting.
    When KEY
    is specified the compression routine is allowed to compress the
    sequence field in the segment, as well as any data following
    it. It is
    possible that the resulting compressed segment data will be
    shorter
    than the uncompressed sequence field, resulting in the
    validation code
    incorrectly failing the request. The validation code should not
    verify
    that the data to be encrypted is longer than the sequence field
    length
    when compression is also being performed and KEY has been
    specified.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: An ABENDU2990 RSNC4C5C3A6 may occur     *
    *                      when an IMS COMPRTN specifies KEY and   *
    *                      the segment data is compressed prior to *
    *                      being encrypting. When KEY is specified *
    *                      the compression routine is allowed to   *
    *                      compress the sequence field in the      *
    *                      segment, as well as any data following  *
    *                      it. It is possible that the resulting   *
    *                      compressed segment data will be shorter *
    *                      than the uncompressed sequence field,   *
    *                      resulting in the validation code        *
    *                      incorrectly failing the request. The    *
    *                      validation code should not verify that  *
    *                      the data to be encrypted is longer than *
    *                      the sequence field length when          *
    *                      compression is also being performed and *
    *                      KEY has been specified.                 *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PI78851

  • Reported component name

    DATA ENCRYPTION

  • Reported component ID

    5655P0300

  • Reported release

    120

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-03-27

  • Closed date

    2017-04-25

  • Last modified date

    2017-05-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI46689

Modules/Macros

  • DECENAA1 DECENA01 DECENBB1 DECENB01 DECENC01
    

Fix information

  • Fixed component name

    DATA ENCRYPTION

  • Fixed component ID

    5655P0300

Applicable component levels

  • R120 PSY UI46689

       UP17/04/29 P F704

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.2.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
01 May 2017