Error description
An issue exists where a CMAS may incorrectly update a MASDIR record for the active CICSPLEX. When that occurs, the CMAS is subsequently unable to send anything down to the MAS during a CONNECT, so a MAS will hang during its connect process, until the MASINITTIME time expires. When that occurs, the CMAS EYULOG will have a message similar to the following: . EYUTS0021E CMAS0001 Topology Connect of CICS System MAS00001 failed due to a Resource Topology Collection Time-Out. EYUTS0002E CMAS0001 Topology Connect for MAS00001 Failed - APPLID(MAS00001) CICSplex(PLEX0001). . . Formatting the trace using VERBX EYU9D### 'TRC=A,JOB=cmasname' you will see exception traces similar to the following: . Task Mtd Prev Tran Obj Level Pt-ID Debug 12345 TSSC XLOP TSSC TOP Excp 14 NLGTTOUT 12345 CTBP CAMM TSSC COM Excp 28 TrgtUnav 12345 TSSC XLOP TSSC TOP Excp 20 TSSCCPUM . In the full trace, the MAL for the call to CTBP will show a status of SCOPE_NOT_FOUND . . Additional Symptom(s) Search Keyword(s): TSSC EXCEPTION METHOD_FAILED TISTTSSC CAMMCTBP KIXREVSCB
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICSPlex SM V5R1M0, V5R2M0 and V5R3M0 * * Users * **************************************************************** * PROBLEM DESCRIPTION: Communications related problems can * * occur when CMASes exchange network * * topology information: * * * * - The communications control block for * * a MAS (MASDIR) may be updated * * invalidly. This can result in * * requests that should be sent to the * * MAS to be lost, resulting in time * * outs. * * * * If the MASDIR is updated while the * * MAS is connecting to its CMAS, then * * the connect may fail with variations * * of the following error messages: * * * * EYUTS0021E Topology Connect of * * CICS System <masname> * * failed due to a * * <Resource Topology * * Collection | MAS * * Resource Installation> * * Time-Out. * * * * EYUTS0002E Topology Connect for * * <masname> Failed - * * APPLID(<applid>) * * CICSplex(<plexname>). * * * * - MASes connected to a CMAS may not * * join to other active CMASes that * * manage the CICSplex the MAS is * * associated with, or a CMAS may * * attempt to join a MAS that is not * * active or to which it is already * * connected or joined. * **************************************************************** * RECOMMENDATION: After applying the PTF that resolves this * * APAR, all CMASes must be restarted. Note * * that the restarts do not need to occur at * * the same time. * **************************************************************** When CMASes connect directly or indirectly, they may exchange information about their view of the network at the time of the connect, including what CICSplexes, CMASes and MASes are active. This information usually is routed to all CMASes in the network. It is possible that during this information interchange, a CMAS will receive some of the information more than once, and for old data to be included in the interchange. Two possible problems that can occur during this interchange regarding active MASes have been identified: - When information about a MAS is received through this interchange, method EYU0CPTI (CPTI) determines whether the request is an ADD, UPDATE or DELETE request, and passes that information on to method EYU0CPMI (CPMI): - if the request is an ADD, CPMI will call method EYU0CPAM (CPAM), which will use the provided information to build a MASDIR for the MAS. - if the request is an UPDATE, CPMI will call method EYU0CPUM (CPUM), which will use the provided information to update the existing MASDIR for the MAS. - if the request is an DELETE, CPMI will call method EYU0CPDM (CPDM), which will use the provided information to delete the existing MASDIR for the MAS. The parameter list that CPTI sends to CPMI for an ADD can be corrupted, such that it indicates to CPMI that if the CPAM call indicates that it did not create a MASDIR because one already exists, that CPMI can then call CPUM to update the existing MASDIR. If this occurs and the data that is used to update the MASDIR is stale data, including the information that this MAS is connected to a different CMAS, then subsequent communications requests to the MAS will be directed to the other CMAS, where they will be lost. This can result in the problems documented above. - If the MAS information received for an ADD indicates the the MAS is connected to another CMAS, then CPAM will build an EENDJOIN resource table. This will be delivered to method EYU0CPLT (CPLT), which will then check if the EENDJOIN record was built from stale data. It does this by validating that the time the MAS connected to its CMAS is later than the time its CMAS started. - If CPLT determines that the EENDJOIN request is valid, then it passes the request onto the Topology component, which will initiate a Topology Join request for the MAS. - If CPLT determines that the EENDJOIN request is not valid, then it calls CPDM to delete the MASDIR that was created by CPAM. A logic error in CPLT can result in the wrong CMAS's start time being compared to the MAS connect time. This can result in the problems documented above.
Problem conclusion
To address these problems: - CPTI has been updated to ensure it does not corrupt the parameter list it passes to CPMI for an ADD MAS request. - CPLT has been updated to ensure its uses the start time for the CMAS that the MAS is connected to.
Temporary fix
Comments
APAR Information
APAR number
PI77676
Reported component name
CICS TS Z/OS V5
Reported component ID
5655Y0400
Reported release
90M
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-03-06
Closed date
2017-03-24
Last modified date
2017-04-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
PI77829 UI45858 UI45859 UI45860
Modules/Macros
EYU0CPLT EYU0CPTI
Fix information
Fixed component name
CICS TS Z/OS V5
Fixed component ID
5655Y0400
Applicable component levels
R00M PSY UI45860
UP17/03/28 P F703 ¢
R80M PSY UI45858
UP17/03/28 P F703 ¢
R90M PSY UI45859
UP17/03/28 P F703 ¢
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
03 April 2017