A fix is available
APAR status
Closed as program error.
Error description
Exception in load module IGZXLPKD csect QXCP at offset x'A8' on an MVI instruction (9208 1001) due to an invalid address in reg1. Problem occurs when running with a full volume of data.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Enterprise COBOL V5+ users that are * * compiling and running programs that contain * * QSAM I/O with RERUN clause. * * * **************************************************************** * PROBLEM DESCRIPTION: Runtime ABEND S0C4 in csect QXCP * * module IGZXLPKD when the RERUN action * * execute, if the COBOL Runtime is * * loaded in read-only memory (such as * * LPA). * * * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * * * **************************************************************** CHKPT DFSMS macro was used in an non reentrant way, caused an 0C4 ABEND.
Problem conclusion
The code has been corrected.
Temporary fix
Comments
APAR Information
APAR number
PI76988
Reported component name
LE ENT COBOL LI
Reported component ID
568819812
Reported release
7A0
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-02-21
Closed date
2017-03-20
Last modified date
2017-04-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGZXLPKA
Fix information
Fixed component name
LE ENT COBOL LI
Fixed component ID
568819812
Applicable component levels
Fix is available