Error description

  • VOLCNT not respected when specified in the UTILGBL parms.
    Retro-fit of V2.1 APAR PI71631.
    
    Although APAR/PTF PI72052/UI42953 had a correct fix, the PTF
    had incorrect ++HOLD data.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IMS Database Recovery Facility  *
    *                 with High Performance Image Copy (HPIC).     *
    ****************************************************************
    * PROBLEM DESCRIPTION: When the VOLCNT or DSNTYPE parameter is *
    *                      specified in the UTILGBL parameters     *
    *                      they are not respected and the default  *
    *                      value of 1 is used as the VOLCNT value  *
    *                      and BASIC is used as the DSNTYPE value. *
    *                                                              *
    *                      PTF UI42953 for APAR PI72052 was built  *
    *                      to include ++HOLD cards which were not  *
    *                      required.  The -PE- against UI42953 is  *
    *                      corrected by this APAR.                 *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The parameter validation process looks for VOLCNT and DSNTYPE on
    each line of parameters specified in the SYSIN file.  When the
    VOLCNT parameter is found it is correctly set but if a
    successive SYSIN line is specified after VOLCNT is set the
    default value of 1 replaces the VOLCNT previously validated and
    set.
    
    When DSNTYPE is specified in the UTILGBL parameters RWSP_COMPRTN
    is incorrectly used when setting the final value for DSNTYPE.
    
    The fix in -PE- PTF UI42953 is packaged with ++HOLD which are
    not required.
    

Problem conclusion

  • FRXVASD0 and FRXVWSP is corrected to set VOLCNT to the default
    of 1 only after all SYSIN parameters have be processed and no
    VOLCNT found0
    
    FRXVASD0 is corrected to use RWSP_DSNTYPE when setting the final
    value for DSNTYPE.
    
    FRXEDRF0 and FRXEPSS0 are re-compiled to pick up the changes in
    FRXVWSP.
    
    The fix in -PE- PTF UI42953 is re-packaged with no ++HOLD.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI75935

  • Reported component name

    IMS RCVR SOLUTN

  • Reported component ID

    5655V8600

  • Reported release

    110

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-02-02

  • Closed date

    2017-02-06

  • Last modified date

    2017-03-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI44449

Modules/Macros

  • FRXEDRF0 FRXEPSS0 FRXVASD0
    

Fix information

  • Fixed component name

    IMS RCVR SOLUTN

  • Fixed component ID

    5655V8600

Applicable component levels

  • R110 PSY UI44449

       UP17/02/10 P F702 Ø

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.1.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
02 March 2017