A fix is available
APAR status
Closed as program error.
Error description
VOLCNT not respected when specified in the UTILGBL parms. Retro-fit of V2.1 APAR PI71631. Although APAR/PTF PI72052/UI42953 had a correct fix, the PTF had incorrect ++HOLD data.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IMS Database Recovery Facility * * with High Performance Image Copy (HPIC). * **************************************************************** * PROBLEM DESCRIPTION: When the VOLCNT or DSNTYPE parameter is * * specified in the UTILGBL parameters * * they are not respected and the default * * value of 1 is used as the VOLCNT value * * and BASIC is used as the DSNTYPE value. * * * * PTF UI42953 for APAR PI72052 was built * * to include ++HOLD cards which were not * * required. The -PE- against UI42953 is * * corrected by this APAR. * **************************************************************** * RECOMMENDATION: * **************************************************************** The parameter validation process looks for VOLCNT and DSNTYPE on each line of parameters specified in the SYSIN file. When the VOLCNT parameter is found it is correctly set but if a successive SYSIN line is specified after VOLCNT is set the default value of 1 replaces the VOLCNT previously validated and set. When DSNTYPE is specified in the UTILGBL parameters RWSP_COMPRTN is incorrectly used when setting the final value for DSNTYPE. The fix in -PE- PTF UI42953 is packaged with ++HOLD which are not required.
Problem conclusion
FRXVASD0 and FRXVWSP is corrected to set VOLCNT to the default of 1 only after all SYSIN parameters have be processed and no VOLCNT found0 FRXVASD0 is corrected to use RWSP_DSNTYPE when setting the final value for DSNTYPE. FRXEDRF0 and FRXEPSS0 are re-compiled to pick up the changes in FRXVWSP. The fix in -PE- PTF UI42953 is re-packaged with no ++HOLD.
Temporary fix
Comments
APAR Information
APAR number
PI75935
Reported component name
IMS RCVR SOLUTN
Reported component ID
5655V8600
Reported release
110
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-02-02
Closed date
2017-02-06
Last modified date
2017-03-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI44449
Modules/Macros
FRXEDRF0 FRXEPSS0 FRXVASD0
Fix information
Fixed component name
IMS RCVR SOLUTN
Fixed component ID
5655V8600
Applicable component levels
R110 PSY UI44449
UP17/02/10 P F702 Ø