PI72936: LASTPITCA RECOVERY TO EMPTY PITCA FAILS FOR NON-%SYS TIMEZIN

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • LASTPITCA recovery to empty PITCA fails for non-%SYS TIMEZIN.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IBM IMS High Performance Change *
    *                 Accumulation V1.1.                           *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1- No indication of error is provided   *
    *                      during conversion of time stamp values. *
    *                      2- NOTIFY.CA processing provides no     *
    *                      time zone offset allowing the TIMEZIN   *
    *                      offset to be used.                      *
    *                      3- PITCA is created with a STOPTIME     *
    *                      prior to the STOPTIME of an existing    *
    *                      CA.                                     *
    ****************************************************************
    * RECOMMENDATION: APPLY the correcting PTF.                    *
    ****************************************************************
    1- No indication of time stamp format conversion errors could
    complicate future problem determination.
    2- If the default TIMEZIN setting in the DBRC is changed after a
    CA is created then a PITCA is later created from that CA and
    registered in the DBRC without specifying the time zone offset
    that PITCA will be unusable for a LASTPITCA recovery.
    3- It is not valid to create a PITCA to a point in time prior to
    an existing CA.
    

Problem conclusion

  • 1- Code is added to test for errors following time stamp format
    Conversions.  If an error occurs new message HPC4026W is issued.
    2- Code is added to retrieve the time zone offset of the CA used
    to create a PITCA and that same offset is used on the NOTIFY.CA
    to register the PITCA in the DBRC.  After the fix is APPLY-ed
    the time stamp and offset of any PITCA created from a CA will be
    derived from the CA.
    3- Code is added to reject the PITCA request with new message
    HPC4013W if any valid CA exists with a time stamp later then the
    LOG TIME= value specified on the PITCA request.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI72936

  • Reported component name

    IMS RCVR SOLUTN

  • Reported component ID

    5655V8600

  • Reported release

    110

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-11-29

  • Closed date

    2017-03-23

  • Last modified date

    2017-04-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI45797

Modules/Macros

  • HPCALST0
    

Publications Referenced
SC19290500    

Fix information

  • Fixed component name

    IMS RCVR SOLUTN

  • Fixed component ID

    5655V8600

Applicable component levels

  • R110 PSY UI45797

       UP17/03/24 P F703

Fix is available