A fix is available
APAR status
Closed as program error.
Error description
VOLCNT not respected when specified in the UTILGBL parms. Retro-fit of V2.1 APAR PI71631.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IMS Database Recovery Facility * * with High Performance Image Copy (HPIC). * **************************************************************** * PROBLEM DESCRIPTION: When the VOLCNT or DSNTYPE parameter is * * specified in the UTILGBL parameters it * * is not respected and the default value * * of 1 is ued as the VOLCNT value and * * BASIC is used as the DSNTYPE value. * **************************************************************** * RECOMMENDATION: * * Specify VOLCNT and/or DSNTYPE in the IC parameters. * **************************************************************** The parameter validation process looks for VOLCNT and DSNTYPE on each line of parameters specified in the SYSIN file. When the VOLCNT parameter is found it is correctly set but if a successive SYSIN line is specified after VOLCNT is set the default value of 1 replaces the VOLCNT previously validated and set. When DSNTYPE is specified in the UTILGBL parameters RWSP_COMPRTN is incorrectly used when setting the final value for DSNTYPE.
Problem conclusion
IMS Database Recovery Facility is corrected to set VOLCNT to the default of 1 only after all SYSIN parameters have been processed and no VOLCNT is found and to use RWSP_DSNTYPE when setting the final value for DSNTYPE.
Temporary fix
Comments
×**** PE17/02/02 PTF IN ERROR. SEE APAR PI75935 FOR DESCRIPTION
APAR Information
APAR number
PI72052
Reported component name
IMS RCVR SOLUTN
Reported component ID
5655V8600
Reported release
110
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-11-09
Closed date
2016-11-29
Last modified date
2017-02-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI42953
Modules/Macros
FRXEDRF0 FRXEPSS0 FRXVASD0
Fix information
Fixed component name
IMS RCVR SOLUTN
Fixed component ID
5655V8600
Applicable component levels
R110 PSY UI42953
UP17/01/18 P F701
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.1.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
06 February 2017