Error description

  • When a PE Server modify command is issued to start Performance
    Warehouse (PWH) although it has not been configured, the PWH is
    attached but abends immediately with system completion code S978
    instead of rejecting the start command.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component                           *
    *                 - PE Server subtask                          *
    ****************************************************************
    * PROBLEM DESCRIPTION: Performance Warehouse abends when being *
    *                      started without having been configured. *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF.                              *
    ****************************************************************
    PROBLEM SUMMARY:
    When a PE Server modify command is issued to start Performance
    Warehouse (PWH) although it has not been configured, PE Server
    does not reject the start command. The PWH load module FPEZPMS
    is attached and abends immediately with system completion code
    S978.
    
    PROBLEM CONCLUSION:
    The code has been corrected accordingly to reject the PE Server
    modify command to start Performance Warehouse (PWH) if PWH has
    not been configured. Message FPEV0271W is issued.
    
    KEYWORDS:
    PERFORMANCE WAREHOUSE PWH FPEZPMS ABEND S978
    

Problem conclusion

  • The code has been corrected accordingly to reject the PE Server
    modify command to start Performance Warehouse (PWH) if PWH has
    not been configured. Message FPEV0271W is issued.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI71869

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    540

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-11-07

  • Closed date

    2016-12-01

  • Last modified date

    2017-01-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI43044

Modules/Macros

  • DGOVMSTR DGOZPWH  DGOZSUB1 FPEVM000
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R540 PSY UI43044

       UP16/12/09 P F612

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
03 January 2017