IBM Support

PI70360: ABENDS0C1 IN PANEL IRTOPG6 WHEN YOU IMMEDIATELY ENTER A CANCEL COMMAND

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ABENDS0C1 in panel IRTOPG6 when you immediately enter a CANCEL
    command. Additional minor ISPF panel fixes included in this
    APAR.
    

Local fix

  • Don't enter cancel command from this panel unless you must back
    out a prior action performed on one of this panel's subpanels.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Users of Program Restart Facility V2R2.  *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1. When entering Option 5 (Global       *
    *                      Options), then Option 6 (DLI logs),     *
    *                      then immediately issuing a CANCEL       *
    *                      command, the ISPF session will          *
    *                      encounter a S0C1 abend.                 *
    *                      2. The help panel for updating Abend    *
    *                      Retry tables (IRTZ8000) has a           *
    *                      mis-spelling of the word "table", as    *
    *                      "tablem".                               *
    *                      3. The Update Job Override Options      *
    *                      panel generates a Panel not found error *
    *                      when you enter PF1 on a line entry.     *
    *                      4. The Update IMS Groups panel          *
    *                      generates a Panel not found error when  *
    *                      you enter PF1 on a line entry.          *
    *                      5. The Global General Options panel     *
    *                      requires a value for the SYSOUT entry   *
    *                      although the SYSOUT entry is not marked *
    *                      as being required.                      *
    *                      6. On the Show Options for a Specific   *
    *                      Job Step panel (IRTJOPT1), entering     *
    *                      CANCEL brings you to the results panel  *
    *                      (IRTJOPT2) instead of the PRF primary   *
    *                      options panel.                          *
    *                      7. After specifying job information on  *
    *                      the Show Options for a Specific Job     *
    *                      Step panel (IRTJOPT1), hitting ENTER    *
    *                      will get you to the results panel       *
    *                      (IRTJOPT2). Typing CANCEL or entering   *
    *                      PF3 on panel IRTJOPT2 will bring you to *
    *                      the PRF main panel instead of back to   *
    *                      panel IRTJOPT1.                         *
    ****************************************************************
    * RECOMMENDATION: Apply the PTF that corrects this APAR.       *
    ****************************************************************
    1. The program which processes the panel input saves the old
    values of the input prior to processing new input. The address
    where the old panel input is saved is stored in the program's
    working storage. The program logic does not correcly initialize
    this address, but sets it correctly when input values are
    changed. This results in an invalid value for this address if
    you get to the panel and enter CANCEL without making changes,
    leading to the S0C1.
    2. Mis-spelling in the panel text.
    3. Field-level help was defined on a panel that didn't need it.
    4. Field-level help was defined on a panel that didn't need it.
    5. The Global SYSOUT value is not defined as required in the
    panel, but is required.
    6. CANCEL processing for this panel should go back to the prior
    panel. Instead, it causes the panel input to be processed.
    7. CANCEL or END processing for this panel should go back to
    the prior panel. Instead, it goes back to the main panel.
    

Problem conclusion

  • 1. The program has been modified to correctly initialize
    working storage.
    2. The spelling has been corrected.
    3. The field level help definition was removed from the panel.
    4. The field level help definition was removed from the panel.
    5. The Global SYSOUT value has been marked as required.
    6. CANCEL processing for this panel has been corrected.
    7. CANCEL and END processing for this panel has been corrected.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI70360

  • Reported component name

    IMS PGM RESTART

  • Reported component ID

    5655E1400

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-10-07

  • Closed date

    2016-11-02

  • Last modified date

    2016-12-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI42220

Modules/Macros

  •    IRTC09   IRTJOPT1 IRTOPG1  IRTOPI   IRTOPJT
    IRTOPTL  IRTPRE00 IRTZGETV IRTZINIT IRTZJOPT IRTZOPGE IRTZPUTV
    IRTZ1000 IRTZ8000
    

Fix information

  • Fixed component name

    IMS PGM RESTART

  • Fixed component ID

    5655E1400

Applicable component levels

  • R220 PSY UI42220

       UP16/11/03 P F611

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSAVHR","label":"IMS Program Restart Facility for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220"}]

Document Information

Modified date: