A fix is available
APAR status
Closed as program error.
Error description
ABENDS0C1 in panel IRTOPG6 when you immediately enter a CANCEL command. Additional minor ISPF panel fixes included in this APAR.
Local fix
Don't enter cancel command from this panel unless you must back out a prior action performed on one of this panel's subpanels.
Problem summary
**************************************************************** * USERS AFFECTED: All Users of Program Restart Facility V2R2. * **************************************************************** * PROBLEM DESCRIPTION: 1. When entering Option 5 (Global * * Options), then Option 6 (DLI logs), * * then immediately issuing a CANCEL * * command, the ISPF session will * * encounter a S0C1 abend. * * 2. The help panel for updating Abend * * Retry tables (IRTZ8000) has a * * mis-spelling of the word "table", as * * "tablem". * * 3. The Update Job Override Options * * panel generates a Panel not found error * * when you enter PF1 on a line entry. * * 4. The Update IMS Groups panel * * generates a Panel not found error when * * you enter PF1 on a line entry. * * 5. The Global General Options panel * * requires a value for the SYSOUT entry * * although the SYSOUT entry is not marked * * as being required. * * 6. On the Show Options for a Specific * * Job Step panel (IRTJOPT1), entering * * CANCEL brings you to the results panel * * (IRTJOPT2) instead of the PRF primary * * options panel. * * 7. After specifying job information on * * the Show Options for a Specific Job * * Step panel (IRTJOPT1), hitting ENTER * * will get you to the results panel * * (IRTJOPT2). Typing CANCEL or entering * * PF3 on panel IRTJOPT2 will bring you to * * the PRF main panel instead of back to * * panel IRTJOPT1. * **************************************************************** * RECOMMENDATION: Apply the PTF that corrects this APAR. * **************************************************************** 1. The program which processes the panel input saves the old values of the input prior to processing new input. The address where the old panel input is saved is stored in the program's working storage. The program logic does not correcly initialize this address, but sets it correctly when input values are changed. This results in an invalid value for this address if you get to the panel and enter CANCEL without making changes, leading to the S0C1. 2. Mis-spelling in the panel text. 3. Field-level help was defined on a panel that didn't need it. 4. Field-level help was defined on a panel that didn't need it. 5. The Global SYSOUT value is not defined as required in the panel, but is required. 6. CANCEL processing for this panel should go back to the prior panel. Instead, it causes the panel input to be processed. 7. CANCEL or END processing for this panel should go back to the prior panel. Instead, it goes back to the main panel.
Problem conclusion
1. The program has been modified to correctly initialize working storage. 2. The spelling has been corrected. 3. The field level help definition was removed from the panel. 4. The field level help definition was removed from the panel. 5. The Global SYSOUT value has been marked as required. 6. CANCEL processing for this panel has been corrected. 7. CANCEL and END processing for this panel has been corrected.
Temporary fix
Comments
APAR Information
APAR number
PI70360
Reported component name
IMS PGM RESTART
Reported component ID
5655E1400
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-10-07
Closed date
2016-11-02
Last modified date
2016-12-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI42220
Modules/Macros
IRTC09 IRTJOPT1 IRTOPG1 IRTOPI IRTOPJT IRTOPTL IRTPRE00 IRTZGETV IRTZINIT IRTZJOPT IRTZOPGE IRTZPUTV IRTZ1000 IRTZ8000
Fix information
Fixed component name
IMS PGM RESTART
Fixed component ID
5655E1400
Applicable component levels
R220 PSY UI42220
UP16/11/03 P F611
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSAVHR","label":"IMS Program Restart Facility for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220"}]
Document Information
Modified date:
24 January 2022