APAR status
Closed as program error.
Error description
IBM Rational Developer for z Systems (RDz) If you attempt to use the COBOL Scan for compatibility for two COBOL programs you may receive an incompatibility even though one does not exist. You may see an error such as: "CRRZI0788E PROGA is using 3 parms but PROGB expects 4 parms." Or, you may get a message such as: "CRRZI0791E PROGA is incompatible with PROGB; Parameter 2 has a size of 1601 but MUXRE is expecting a size 0."" In this case, PROGA contains the following in the LINKAGE SECTION: 01 RCV-STRUC. COPY TEST1. And with a PROCEDURE statement such as: PROCEDURE DIVISION USING RCV-GRP RCV-STRUC RELEASE-DATES. The COBOL parser will flag an error for the procedure statement stating, "Ambiguous reference to RCV-STRUC". The RCV-STRUC is defined in the copybook TEST1.
Local fix
Remove from the Linkage Section the line: 01 RCV-STRUC.
Problem summary
The COBOL Scan for compatibility can incorrectly report errors in a couple cases. First, it can get the number of expected parameters wrong. Second it can miscalculate an expected parameter size when data from a copybook is needed to determine that number, particularly if the member to scan had not been opened in an editor before.
Problem conclusion
The scan was getting the wrong number of parameters because it was not properly reading the linkage section. The wrong expected parameter size came about because the scanner failed to determine the SYSLIB as a result of not finding the associated property group; a session object mapping the local temp file with the remote member is needed for this but it was not set if the editor had not be opened before. The problem listed in this APAR has been resolved with IBM Rational Developer for z Systems V9.5.1.3 Fix Pack which is available from the Recommended Fixes support download page: http://www-1.ibm.com/support/docview.wss?rs=2294&uid=swg27006335
Temporary fix
Comments
APAR Information
APAR number
PI70248
Reported component name
EXP FOR Z/OS CL
Reported component ID
5655EXP00
Reported release
950
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-10-05
Closed date
2016-11-21
Last modified date
2016-11-21