PI69874: CLONE - IF DB2 STAP STAYS UP AND CQM IS RECYCLED A MEMORY OBJECTNEEDS TO BE DETACHED FROM THE DBM1 AND THE CQM MASTER ADDRESS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • For Query Monitor v31 ( PI68136 code ) compatability for STP9.0
    

Local fix

  • Anytime CQM needs to be recycled, also restart STAP. This must
    be done in the following order:
     .
     1. STOP STAP
     2. STOP CQM
     3. START STAP and CQM
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IBM DB2 Query Monitor z/OS.         *
    ****************************************************************
    * PROBLEM DESCRIPTION: For Query Monitor v31 ( PI68136 code )  *
    *                      compatability for STP9.0                *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI69874

  • Reported component name

    DB2 QUERY MONIT

  • Reported component ID

    5655E6701

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-09-28

  • Closed date

    2016-10-18

  • Last modified date

    2016-11-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI41772

Modules/Macros

  • CQM#REST
    

Fix information

  • Fixed component name

    DB2 QUERY MONIT

  • Fixed component ID

    5655E6701

Applicable component levels

  • R310 PSY UI41772

       UP16/10/25 P F610

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.