Fixes are available
APAR status
Closed as program error.
Error description
The performance degradation occurs because the logic detects the same variable when it was simply a variable and not when it was enclosed in a record. That enclosing caused the logic to think it was a different variable and hence needed to create a string to hold the intermediate value, instead of the higher performing logic.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Applications that use the same substring variable for both * * parts of the substring, and that variable is a field within * * a record. * **************************************************************** * PROBLEM DESCRIPTION: * * Performance degradation with using substring values with the * * same record variable for both the from and to indecies. This * * is because the logic detects the same variable when it was * * simply a variable and not when it was enclosed in a record. * * That enclosing caused the logic to think it was a different * * variable and hence needed to create a string to hold the * * intermediate value, instead of the higher performing logic. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
The software has been updated to check for record variables correctly
Temporary fix
Comments
APAR Information
APAR number
PI68188
Reported component name
RATL BUS DEV
Reported component ID
5724S5000
Reported release
950
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-08-26
Closed date
2019-01-17
Last modified date
2019-01-17
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL BUS DEV
Fixed component ID
5724S5000
Applicable component levels
R901 PSY
UP
R911 PSY
UP
R950 PSY
UP