Error description

  • 1 An IMS PI Batch Job run with an 'Active Tracking' Filter may
    receive an abend S0C4 if the selected records contain an MQ
      Logtoken.
    2 Updates are required to some Knowledge Modules as a result of
      IMS service updates.
    
    Summary of changes
    1 If records selected for Tracking contain an MQ Logtoken the
      Logtoken will be used as a unique key to locate a queue entry
      which contains information used in the tracking process. In
      some circumstances for the MQ Logtoken the locate process is
      not being performed,  which results in an invalid queue entry
      being accessed, leading to unpredictable results including
      S0C4 abends.
    2 Updates are required to some Knowledge Modules as a result of
      IMS service up to PUT1606.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IMS Problem Investigator V2.4.      *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1. An IMS PI Batch Job run with an      *
    *                       'Active Tracking' Filter may receive   *
    *                       an abend S0C4 if the selected records  *
    *                       contain an MQ Logtoken                 *
    *                      2. Updates are required to some         *
    *                        Knowledge Modules as a result of IMS  *
    *                        service updates.                      *
    *                                                              *
    *                      Summary of changes:                     *
    *                                                              *
    *                      1. If records selected for Tracking     *
    *                       contain an MQ Logtoken the Logtoken    *
    *                       will be used as a unique key to        *
    *                       locate a queue entry which contains    *
    *                       information used in the tracking       *
    *                       process. In some circumstances for     *
    *                       the MQ Logtoken the locate process is  *
    *                       not being performed, which results in  *
    *                       an invalid queue entry being accessed, *
    *                       leading to unpredictable results       *
    *                       including S0C4 abends                  *
    *                      2. Updates are required to some         *
    *                       Knowledge Modules as a result of IMS   *
    *                       service up to PUT1606                  *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI65841

  • Reported component name

    IMS PROBLEM INV

  • Reported component ID

    5655K5000

  • Reported release

    240

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-07-14

  • Closed date

    2016-07-21

  • Last modified date

    2016-08-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI39551

Modules/Macros

  • ALZAL01Y ALZAT00Y ALZAT01Y ALZA0AA9 ALZA0AB9
    ALZA0AC9 ALZA0AD9 ALZA0AE9 ALZA0A09 ALZA0A19 ALZA0A29 ALZA0A
    
    ***This field was truncated.  To obtain the full apar record, please contact your local support center.***
    

Fix information

  • Fixed component name

    IMS PROBLEM INV

  • Fixed component ID

    5655K5000

Applicable component levels

  • R240 PSY UI39551

       UP16/07/26 P F607

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.4.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A4","label":"IMS Problem Investigator"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.4.0","Edition":"","Line of Business":{"code":"","label":""}}]