A fix is available
APAR status
Closed as new function.
Error description
Customer requirement to write a specified message (FUN2515I) to the SYSLOG as well as to CEXPRINT. Summary of changes A new control option MESSAGE with suboptions ADD_WTO and DROP_CEXPRINT, for example: >>----MESSAGE--ADD_WTO=(2515),DROP_CEXPRINT=(2515)---->><< The ADD_WTO suboption accepts a list of one or more message numbers and adds the WTO destination to each message in the list. The DROP_CEXPRINT suboption accepts a list of one or more message numbers and removes the CEXPRINT destination from each message in the list.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Connect Extensions * **************************************************************** * PROBLEM DESCRIPTION: 1. Customer requirement to write a * * specified message (FUN2515I) to the * * SYSLOG as well as to CEXPRINT. * **************************************************************** * RECOMMENDATION: APPLY the PTF. * **************************************************************** 1. A new control option MESSAGE with suboptions ADD_WTO and DROP_CEXPRINT, for example: >>----MESSAGE--ADD_WTO=(2515),DROP_CEXPRINT=(2515)---->><< The ADD_WTO suboption accepts a list of one or more message numbers and adds the WTO destination to each message in the list. The DROP_CEXPRINT suboption accepts a list of one or more message numbers and removes the CEXPRINT destination from each message in the list.
Problem conclusion
APPLY the PTF.
Temporary fix
Comments
APAR Information
APAR number
PI65651
Reported component name
IMS CONNECT EXT
Reported component ID
5655K4800
Reported release
240
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2016-07-12
Closed date
2016-07-27
Last modified date
2018-11-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
CEXCPSR CEXDFN1 CEXMAIN CEXMSGCM CEXMSGL CEXMSGT CEXMSGX H28S240J
Fix information
Fixed component name
IMS CONNECT EXT
Fixed component ID
5655K4800
Applicable component levels
R240 PSY UI39698
UP16/08/15 P F608
Fix is available