A fix is available
APAR status
Closed as program error.
Error description
After applying APAR PI59811 (PTF UI36929), ABENDU4013 with FABH0855E is issued incorrectly: FABH0855E COMPRESSION EXIT ROUTINE xxxxxxxx INITIALIZATION ERROR This error occurs if register 0 is not modified in the INIT function of the compression exit routine. Register 0 should be set to zero before calling exit.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IMS High Performance Unload for * * z/OS Version 1 Release 2 (FMID=H1IN120) * **************************************************************** * PROBLEM DESCRIPTION: After applying APAR PI59811, the HSSR * * engine of HP Unload issues ABENDU4013 * * with FABH0855E incorrectly depending on * * the compression exit routine. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** After applying APAR PI59811, the HSSR engine of HP Unload issues ABENDU4013 with FABH0855E incorrectly depending on the compression exit routine. FABH0855E COMPRESSION EXIT ROUTINE xxxxxxxx INITIALIZATION ERROR This error occurs if register 0 is not modified in the INIT function of the compression exit routine. The HSSR engine should set the register 0 to zero before calling exit.
Problem conclusion
Code has been added to correct the issue.
Temporary fix
Comments
APAR Information
APAR number
PI63957
Reported component name
IMS HIGHPERF UN
Reported component ID
5655E0600
Reported release
120
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-06-09
Closed date
2016-06-20
Last modified date
2016-07-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI38812
Modules/Macros
FABHGSP FABH040 FABH060 FABH200A FABH200B FABH2002 FABH2003 FABH2004 FABH2008 FABH2009 FABH250A FABH250B FABH2502 FABH2503 FABH2504 FABH2508 FABH2509
Fix information
Fixed component name
IMS HIGHPERF UN
Fixed component ID
5655E0600
Applicable component levels
R120 PSY UI38812
UP16/06/23 P F606 Ø
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10"},"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSCX89K","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.2.0"}]
Document Information
Modified date:
14 December 2020