Error description

  • If a system level backup is run after a change to the profile is
    performed and a setup job has not been run a S0C4 abend may
    occur in module ARY@BAKE after the ARYS078E message is produced.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IBM DB2 Recovery Expert z/OS.       *
    ****************************************************************
    * PROBLEM DESCRIPTION: If a system level backup is run after   *
    *                      a change to the profile is performed    *
    *                      and a setup job has not been run a      *
    *                      S0C4 abend may occur in module          *
    *                      ARY@BAKE after the ARYS078E message is  *
    *                      produced.                               *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI63954

  • Reported component name

    DB2 REC EXPERT

  • Reported component ID

    5697H7400

  • Reported release

    320

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-06-09

  • Closed date

    2016-07-12

  • Last modified date

    2016-08-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    ARY$BSAU ARY@BACK ARY@BAKE ARY@REST ARY@SIMG
    ARYFR12  ARYFR64  ARYINB   ARYINBR  ARYINBX  ARYINBXR ARYIN1
    ARYIN1R  ARYIN1X  ARYIN1XR ARYIN4   ARYIN4R  ARYIN4X  ARYIN4XR
    ARYSBKPJ
    

Fix information

  • Fixed component name

    DB2 REC EXPERT

  • Fixed component ID

    5697H7400

Applicable component levels

  • R320 PSY UI39335

       UP16/07/22 P F607

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.