Error description

  • The Accelerator Loader started task may consume a large amount
    of CSA below the line storage.  The amount of storage consumed
    may increase over the life of the started task.
    
    Additional symptoms:
    .
    1. The Loader started task ends abnormally with message:
     HLOS0909S Started task subtask ESTAE entered System RC=0C4
    .
    2. Load job ends with errors:
     HLOU5713E  IDAA stored procedure ACCEL_GET_TABLES_DETAILS
                returned an error.
     HLOS0202E  DSNT404I SQLCODE = 466, WARNING: PROCEDURE
               ACCEL_GET_TABLES_DETAILS RETURNED 2 QUERY RESULT SETS
    .
    3. When a load is run using a SYSREC which contains a TIMESTAMP
    column,  rows are discarded that contain a time of
    24.00.00.000000. The following messages are produced by the job:
    HLOU5807W Column TIMESTAMP has invalid data
    HLOU5816I Total record(s) discarded during data validation=n
    

Local fix

  • Turn Audit and Logging off in the Options document by setting
    AUDIT_ACTIVE="NO" and LOGGING_ACTIVE="NO".
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Analytics Accelerator Loader    *
    *                 for z/OS                                     *
    ****************************************************************
    * PROBLEM DESCRIPTION: The Accelerator Loader started task     *
    *                      consumes CSA storage below the line.    *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The Accelerator Loader started task may consume a large amount
    of CSA below the line storage.  The amount of storage consumed
    of CSA below the line storage.  The amount of storage consumed
    may increase over the life of the started task.
    
    Additional symptoms:
    
    1. The Loader started task ends abnormally with message:
     HLOS0909S Started task subtask ESTAE entered System RC=0C4
    .
    2. Load job ends with errors:
     HLOU5713E  IDAA stored procedure ACCEL_GET_TABLES_DETAILS
                returned an error.
     HLOS0202E  DSNT404I SQLCODE = 466, WARNING: PROCEDURE
              ACCEL_GET_TABLES_DETAILS RETURNED 2 QUERY RESULT SETS
    
    3. When a load is run using a SYSREC which contains a TIMESTAMP
    column,  rows are discarded that contain a time of
    24.00.00.000000. The following messages are produced by the job:
    HLOU5807W Column TIMESTAMP has invalid data
    HLOU5816I Total record(s) discarded during data validation=n
    

Problem conclusion

  • Code has been modified to correct this issue.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI60836

  • Reported component name

    IDAA LOADER ZOS

  • Reported component ID

    5639OLA00

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-04-14

  • Closed date

    2016-06-24

  • Last modified date

    2016-09-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI38942 UI38943

Modules/Macros

  •    HLOBCOMX HLOGMSGF HLORUSQA HLOSINIT HLOSTCMD
    HLOSTDB2 HLOSTMGR HLOSTMSG HLOSTRES HLOSTSES HLOSTSRV HLOSUSQA
    HLOUCE15 HLOUMAIN HLOURCES HLOVSSVC
    

Fix information

  • Fixed component name

    IDAA LOADER ZOS

  • Fixed component ID

    5639OLA00

Applicable component levels

  • R110 PSY UI38942

       UP16/07/01 P F606

  • R210 PSY UI38943

       UP16/07/01 P F606

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSKRKK","label":"IBM Db2 Analytics Accelerator Loader for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
12 September 2016