Error description
When a long running stub has a jTDS connection to a SQL Server (and test actions which make use of that connection) then if the connection reaches a disconnected state then the stub will subsequently fail to respond. Restarting the stub is insufficient (presumably because the connection remains broken) and to fix the problem the Agent needs to be restarted. (If the same happens in RIT the connection could be manually disconnected.) It is likely that this is true of all database connections. Since the connection is a pooled connection the disconnection should be identified and fixed before use, e.g. after the start of the database action, or the invocation of the stub at the time of the pooled resource allocation; and at those times for pooled resource items which remain allocated to the current process.
Local fix
There is no known preventative measure which can be taken. When this occurs on RIT-Agent restart the Agent. In IBM Rational Integration Tester (RIT) use Architecture School and right click the connection and select "disconnect", then restart the stub.
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of Rational Integration Tester accessing a database * * with a driver that does not support all of the JDBC 4.0 * * methods. * **************************************************************** * PROBLEM DESCRIPTION: * * When checking connectivity to a database, the application * * uses methods present within the JDBC 4.0 specification to * * check the validity of the connection, in some older drivers * * these are not available and prevent re-connection from being * * possible. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
In Rational Integration Tester 9.2 a fallback mechanism is used to determine database connection validity allowing older drivers to be used.
Temporary fix
Comments
APAR Information
APAR number
PI59220
Reported component name
RATL INTEGRA TE
Reported component ID
5725G79IT
Reported release
860
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-03-16
Closed date
2018-04-23
Last modified date
2018-04-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL INTEGRA TE
Fixed component ID
5725G79IT
Applicable component levels
R800 PSN
UP
R801 PSN
UP
R850 PSN
UP
R851 PSN
UP
R860 PSN
UP
R870 PSN
UP
R871 PSN
UP
R900 PSN
UP
R901 PSN
UP
R910 PSN
UP
R911 PSN
UP
R920 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSBLQQ","label":"Rational Test Workbench"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.6","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date: