Error description
HP Load ignores the RKSIZE option of the DBD LCHILD statement for a PSINDEX when creating WFP data sets. When the RKSIZE value is greater than the length of the HALDB root key, the key offset of PSINDEX in WFP is incorrect. This causes a VSAM PUT error in the subsequent Index Builder step when using the WFP as input: IIUB048E xxxxxxxx 1208000C VSAM ERROR WHILE LOADING INDEX - REASON=721 VSAM PUT ERROR
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM IMS High Performance Load * * for z/OS Version 2 Release 1 (FMID=H1IM210). * **************************************************************** * PROBLEM DESCRIPTION: PSINDEX RKSIZE is ignored in creating * * WFP data set. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** HP Load ignores the RKSIZE option of the DBD LCHILD statement for PSINDEX in creating WFP data sets. When the RKSIZE value is not the same as the length of HALDB root key, the key offset of PSINDEX in WFP is incorrect. It causes the VSAM PUT error in the subsequent Index Build step when using the WFP as input: IIUB048E xxxxxxxx 1208000C VSAM ERROR WHILE LOADING INDEX - REASON=721 VSAM PUT ERROR
Problem conclusion
Code has been added to correct this issue. To resolve the problem, APAR PI58741 for IBM Index Builder for z/OS Version 3 Release 1 is also required.
Temporary fix
Comments
APAR Information
APAR number
PI58906
Reported component name
IMS HIGH PERF L
Reported component ID
5655E0700
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-03-10
Closed date
2016-04-08
Last modified date
2016-05-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI36886
Modules/Macros
HPSRWFP0 HPSRWFP3 HPSRWFP4
Fix information
Fixed component name
IMS HIGH PERF L
Fixed component ID
5655E0700
Applicable component levels
R210 PSY UI36886
UP16/04/12 P F604
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.