Error description
Metal-C compiler now generates debug related information in the prefix data block, such as DW_AT_location information.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: Debug tools that want to identify * * thelocation of user defined labels. * **************************************************************** * PROBLEM DESCRIPTION: Here we are adding an eyecatcher * * to identify user defined labels to * * CDA,so that CDA can provide its * * locationinformation in debug side file * **************************************************************** * RECOMMENDATION: * **************************************************************** .
Problem conclusion
Per request of our client, we are adding an eyecatcher to identify user labels; with this CDA produces locationinformation in debug side file, and any debug tool is able to convey the location of user label during the debug session.
Temporary fix
Comments
APAR Information
APAR number
PI57133
Reported component name
C/C++ FOR MVS
Reported component ID
56551210A
Reported release
790
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-02-12
Closed date
2016-04-13
Last modified date
2016-06-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
CCNETBY
Fix information
Fixed component name
C/C++ FOR MVS
Fixed component ID
56551210A
Applicable component levels
R790 PSY UI37007
UP16/04/30 P F604
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"790","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSQKCWV","label":"IBM C\/C++ for MVS\/ESA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"790","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]