Error description
The compiler is generating and leaving behind un-necessary tmp files without deleting them after its use. $ date; cob2 test.cbl; ls -l /tmp/SYS* Wed Mar 4 15:33:05 EST 2015 IGYSI5013-U An error occurred while attempting to open file "/gsa/tlbgsa-h1/05/bkanneth/web/private/70791/test.cbl".: No such file or directory The compiler terminated abnormally -rw------- 1 bkanneth staff 0 Mar 04 15:33 /tmp/SYS0y-Xae7a -rw------- 1 hosts/dc staff 0 May 03 2013 /tmp/SYS0y_Gafaa $
Local fix
Manually clean the tmp files.
Problem summary
USERS AFFECTED: COBOL for AIX users compiling any files that may issue an unexpected compiler abend may be affected by this issue. PROBLEM DESCRIPTION: There was a certain path within the compiler where temporary files were being generated, but not deleted after its use.
Problem conclusion
The temporary files are now being deleted after its use.
Temporary fix
Comments
APAR Information
APAR number
PI48347
Reported component name
COBOL FOR AIX
Reported component ID
5724Z8700
Reported release
411
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-09-08
Closed date
2015-09-08
Last modified date
2015-09-09
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
COBOL FOR AIX
Fixed component ID
5724Z8700
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SGM","label":"COBOL for AIX"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"411","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
15 October 2021