IBM Support

PI43147: FPEV0028E XXXX TASK FPEVSERV ABEND0C1

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Keywords:  abend0c1 0c1 FPEV0028E termination
    .
    OMPE Server STC joblog shows:
    .
    CI0970: OMEGAMON SUBTASK ABEND CODE=840C1000
    CI0971: PROGRAM NAME=FPEVSERV
    FPEV0028E  D2HA TASK FPEVSERV ABENDED. CODE 0C1
    FPEV0013I  D2HA TASK FPEVSERV BEING REATTACHED
    FPEV1200I  D2HA APPLICATION SERVICES MAIN TASK START
    FPEV9999I **** DB2 PM/PE SYMPTOM RECORD ****
    FPEV9999I LVLS/OMEGAMON XE PE/PM
    FPEV9999I VALU/PCHK
    FPEV9999I AB/S/0C1
    FPEV9999I AB/U/000
    FPEV9999I RIDS/UNKNOWN#L
    FPEV9999I RIDS/UNKNOWN
    FPEV9999I PTFS/N/A
    FPEV9999I ADRS/N/A
    FPEV9999I PSW /078D2000 80000002
    FPEV9999I REGS 0-1/E3C3D740 90000000
    FPEV9999I REGS 2-3/00000000 2AC07020
    FPEV9999I REGS 4-5/00000000 00000000
    FPEV9999I REGS 6-7/00000000 26FDA18D
    FPEV9999I REGS 8-9/26FDA18D 40404040
    FPEV9999I REGS A-B/40404040 40404040
    FPEV9999I REGS C-D/40404040 A6C4E338
    FPEV9999I REGS E-F/00000000 00000000
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component                           *
    *                 - OMEGAMON collector                         *
    ****************************************************************
    * PROBLEM DESCRIPTION: Intermittent ABEND0C1 during shutdown.  *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF.                              *
    ****************************************************************
    PROBLEM SUMMARY:
    The OMPESTO resource manager was not successfully completing
    because the error recovery mechanism had detected an ABEND0C4.
    
    PROBLEM CONCLUSION:
    Corrected the invalid storage address causing the ABEND0C4 to
    occur.
    
    KEYWORDS:
    ABEND0C1 NON SYSTEM LX SHORTAGE
    

Problem conclusion

  • Corrected the invalid storage address causing the ABEND0C4 to
    occur.
    

Temporary fix

  • *********
    * HIPER *
    *********
    

Comments

APAR Information

  • APAR number

    PI43147

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    520

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-06-16

  • Closed date

    2015-09-30

  • Last modified date

    2017-02-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI31616 UI31617

Modules/Macros

  • KO2OINTB
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R511 PSY UI31616

       UP15/10/03 P F510

  • R520 PSY UI31617

       UP15/10/03 P F510

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]