Error description
Keywords: abend0c1 0c1 FPEV0028E termination . OMPE Server STC joblog shows: . CI0970: OMEGAMON SUBTASK ABEND CODE=840C1000 CI0971: PROGRAM NAME=FPEVSERV FPEV0028E D2HA TASK FPEVSERV ABENDED. CODE 0C1 FPEV0013I D2HA TASK FPEVSERV BEING REATTACHED FPEV1200I D2HA APPLICATION SERVICES MAIN TASK START FPEV9999I **** DB2 PM/PE SYMPTOM RECORD **** FPEV9999I LVLS/OMEGAMON XE PE/PM FPEV9999I VALU/PCHK FPEV9999I AB/S/0C1 FPEV9999I AB/U/000 FPEV9999I RIDS/UNKNOWN#L FPEV9999I RIDS/UNKNOWN FPEV9999I PTFS/N/A FPEV9999I ADRS/N/A FPEV9999I PSW /078D2000 80000002 FPEV9999I REGS 0-1/E3C3D740 90000000 FPEV9999I REGS 2-3/00000000 2AC07020 FPEV9999I REGS 4-5/00000000 00000000 FPEV9999I REGS 6-7/00000000 26FDA18D FPEV9999I REGS 8-9/26FDA18D 40404040 FPEV9999I REGS A-B/40404040 40404040 FPEV9999I REGS C-D/40404040 A6C4E338 FPEV9999I REGS E-F/00000000 00000000
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - OMEGAMON collector * **************************************************************** * PROBLEM DESCRIPTION: Intermittent ABEND0C1 during shutdown. * **************************************************************** * RECOMMENDATION: Apply this PTF. * **************************************************************** PROBLEM SUMMARY: The OMPESTO resource manager was not successfully completing because the error recovery mechanism had detected an ABEND0C4. PROBLEM CONCLUSION: Corrected the invalid storage address causing the ABEND0C4 to occur. KEYWORDS: ABEND0C1 NON SYSTEM LX SHORTAGE
Problem conclusion
Corrected the invalid storage address causing the ABEND0C4 to occur.
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
PI43147
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
520
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-06-16
Closed date
2015-09-30
Last modified date
2017-02-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI31616 UI31617
Modules/Macros
KO2OINTB
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]