Closed as program error.
Error description
If you have a CopyBook like that includes something like : 10 SOMEFIELD-ARRAY-COUNT PIC S9(4). 10 SOMEFIELD-ARRAY OCCURS 1 TO 50 TIMES DEPENDING ON SOMEFILED-ARRAY-COUNT. RIT will miss the SOMEFIELD-ARRAY fields as part of the message sent.
Local fix
A possible workaround is to change the copybook definition of this line: 10 SOMEFIELD-ARRAY-COUNT PIC S9(4). To become 10 SOMEFIELD-ARRAY-COUNT PIC 9(4).
Problem summary
**************************************************************** * USERS AFFECTED: * * All users of Rational Integration Tester working with COBOL * * copybooks. * **************************************************************** * PROBLEM DESCRIPTION: * * Rational Integration Tester incorrectly processed the sign * * character for signed fields in a COBOL copybook such as PIC * * S9(4) under non-EBCDIC character sets. The field was omitted * * when the message was sent. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
A fix for this issue was provided in version 8.6.0.4 of Rational Integration Tester.
Temporary fix
Comments
APAR Information
APAR number
PI42732
Reported component name
RATL INTEGRA TE
Reported component ID
5725G79IT
Reported release
860
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-06-10
Closed date
2015-06-26
Last modified date
2015-06-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL INTEGRA TE
Fixed component ID
5725G79IT
Applicable component levels
R800 PSN
UP
R801 PSN
UP
R850 PSN
UP
R851 PSN
UP
R860 PSY
UP
R870 PSN
UP
Document Information
Modified date:
16 October 2021