PI41969: DFSCLM00 ABEND0C4 DUE TO HP SYSGEN ADDED TRAN WITH CLASS ZERO

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • HP Sysgen allowed a transaction to be added to IMS with class 0,
    which should not be allowed.   Valid IMS transaction classes are
    1-999.  Because a class zero transaction was created, IMS used
    an invalid offset in the TCT latch header which resulted in an
    ABEND0C4 in DFSCLM00.   Class may be found in SMBCLASS.
    
    A workaround is to use the /ASSIGN command to assign a valid
    class to the failing transaction.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IMS HPSysgen v2.3               *
    ****************************************************************
    * PROBLEM DESCRIPTION: DFSCLM00 abend0C4 due to HP SYSGEN      *
    *                      added Tran with class zero              *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    HP Sysgen allowed a transaction to be added to IMS with class 0,
    which should not be allowed.   Valid IMS transaction classes are
    1-999.  Because a class zero transaction was created, IMS used
    an invalid offset in the TCT latch header which resulted in an
    ABEND0C4 in DFSCLM00.   Class may be found in SMBCLASS.
    

Problem conclusion

  • Correct the S0C4 abend when IMS schedules a transaction
    with CLASS 0 that was added via HP SYSGEN ISPF interface.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI41969

  • Reported component name

    IMS HP SYSGEN T

  • Reported component ID

    5655F4300

  • Reported release

    230

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-05-28

  • Closed date

    2015-06-26

  • Last modified date

    2015-07-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI28891

Modules/Macros

  • IOHSDIR0 IOHSDIR1 IOHSDIR2 IOHSDIR3 IOHSDIR4
    IOHTRNA1 IOHZCHK0 IOHZCHK1 IOHZCHK2 IOHZCHK3 IOHZCHK4
    

Fix information

  • Fixed component name

    IMS HP SYSGEN T

  • Fixed component ID

    5655F4300

Applicable component levels

  • R230 PSY UI28891

       UP15/06/30 P F506

Fix is available