A fix is available
APAR status
Closed as program error.
Error description
DBRC continuation character not generated for long keystrings. If your HALDB-DataBase is spread unevenly across 3 partitions. You may want to use the "Maintain"-Utility to correct this. And, you may use long keys to achieve that. You will find that the maintain utility unloads the database successfully. When generat -ing the DBRC commands to change.part the keystrng values that are longer than 80 bytes will not generate a continuation char- acter. So, a DBRC error occurs and the utility stops.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All clients of IMS HALDB Toolkit V3R2. * **************************************************************** * PROBLEM DESCRIPTION: MAINTAIN function with KEYSORDR(Y) can * * fail with ABENDU0999 when long value * * for KEYSTRING is defined. * **************************************************************** * RECOMMENDATION: * **************************************************************** MAINTAIN function with KEYSORDR(Y) can fail with ABENDU0999 when long value for KEYSTRING is defined. Since MAINTAIN function with KEYSORDR(Y) does not generate continuation character for CHANGE.PART DBRC command, it can cause ABENDU0999 with the following messages from DBRC: DSP0210I CLOSING QUOTE DELIMITER MISSING - ONE IS ASSUMED DSP0205I PARENTHESES ERROR AFTER KEYWORD KEYSTRNG DSP0209I PROCESSING TERMINATED WITH CONDITION CODE = 12
Problem conclusion
IHCWTDRC has been changed to generate a continuation character for CHANGE.PART DBRC command when KEYSORDR(Y) is specified.
Temporary fix
Comments
APAR Information
APAR number
PI41766
Reported component name
IMS HALDB C&M A
Reported component ID
5655I0100
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-05-26
Closed date
2015-06-01
Last modified date
2015-07-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI28126
Modules/Macros
IHCULEV0 IHCWTDRC
Fix information
Fixed component name
IMS HALDB C&M A
Fixed component ID
5655I0100
Applicable component levels
R320 PSY UI28126
UP15/06/03 P F506
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.